  1. carol2005

    Fisher 399A-6365 pilot PSV or backpressure regulator on Natural Gas fuel line to Steam Boiler

    I was asked to check the adequacy of a relief valve on some pipelines of supplying natural gas fuel to steam boilers (the steam boilers are to generate 270 pounds of steam for a chemical plant which is located in a place where ASME codes apply). Thesse relief valves all located downstream of...
  2. carol2005

    Take credit for column condensing when reboiler is overboiling?

    Working on sizing a PSV for a column. I am considering the excessive reboiler heat input scenario. In a thermal-siphon reboiler, the process flow is heated in the tube side with steam on the shell side. The control vale on the steam supply senses the column temperature to control the steam flow...
  3. carol2005

    When to use required relief capacity for PSV piping delta P cal

    Some PSV sizing programs provide a feature to calculate PSV inlet and outlet piping pressure loss by using the process required relief rate instead of PSV actual relief capacity. I know ASME VIII Div I appendix M gives recommendation of 3% and 10% limitation for compressible fluid inlet/outlet...
  4. carol2005

    Specify max P/T for process measurement instrumentation

    Here is an opinion on how to specify the max pressure and temperature for process measurement instrumentation. In order to prevent the pressure/temperature rating of the instrumentation becoming a weak point of the system, for the max pressure or temperature specified on the datasheet, process...
  5. carol2005

    Piping for PSV on thermal relief

    I have a question addition to the discussions on thread1203-147200. I agree a norminal D size PSV is more than adequate to handle liquid thermal expansion. Once the PSV spec is determined, can the piping pressure loss calculation be exempted due to the small quantity of the relief load? Does...
  6. carol2005

    Fire Suppression for Residual Fuel Oil burner

    Dealing with steam boilers burn Residual Fuel Oil (*heavy fraction hydrocarbons that are the residues after very high temperature distillation, or so called Vacuum Residual Fuel Oil). The existing fire suppression system is auto water sprinklers (not diluge system). A debate is weather or not...
  7. carol2005

    Fire Suppression for Residual Fuel Oil burner

    Dealing with steam boilers burn Residual Fuel Oil (*heavy fraction hydrocarbons that are the residues after very high temperature distillation, or so called Vacuum Residual Fuel Oil). The existing fire suppression system is auto water sprinklers (not diluge system). A debate is weather or not...
  8. carol2005

    Fire Suppression for Residual Fuel Oil burner

    Dealing with steam boilers burn Residual Fuel Oil (*heavy fraction hydrocarbons that are the residues after very high temperature distillation, or so called Vacuum Residual Fuel Oil). The existing fire suppression system is auto water sprinklers (not diluge system). A debate is weather or not...
  9. carol2005

    Fire Suppression for Residual Fuel Oil burner

    Dealing with steam boilers burn Residual Fuel Oil (*heavy fraction hydrocarbons that are the residues after very high temperature distillation, or so called Vacuum Residual Fuel Oil). The existing fire suppression system is auto water sprinklers (not diluge system). A debate is weather or not...
  10. carol2005

    316SS or Hastelloy C A494 for Operation T up to 500F

    Need to install a Pressure/Vacuum Relief valve on a vessel. Normal operating temperature is as high as 500F. Wondering what material is good for the Pressure/Vacuum Relief Valve? 316 Stainless Steel or Hastelloy C A494? Or select other materials? Thank you for your suggestions.
  11. carol2005

    steam vent & condensate drain during winter time

    Ice formation due to atmospheric vent of steam from Backos Pumpless Pump Backos pumpless pumps are used at my plant for conveying steam condensate. As a design principle, atmospheric vent is required for equalizing the pressue between the condensate receiving chamber and the pumping chamber...
  12. carol2005

    Excess Flow Valve for Rupture Disk Installation

    Excess flow valve is regarded as a accessory for Rupture Disk installation. Not quite sure the purpose of it. Please advise.
  13. carol2005

    PSV two-phase sizing software

    To size PSV under two phase flow relieving condition, please share your experience with me. What type of software do you use?
  14. carol2005

    why no copper parts in PSV

    There are no parts on pressure relief valve made from copper. Why is that?