  1. bosse1950

    Mechanical Bolt On Hot Tap Fittings- are they per Code?

    Can anyone supply me with an actual code reference (or relevant code interpretation) to a permanently attached mechanical hot tap fitting? B31.8 Section 849.6 "Service Line Connections to Mains" makes references to: b)- using a service line clamp or saddle, and c)- using compression fittings...
  2. bosse1950

    Pipeline / Riser Isolation

    I am working on a project where double block & bleed isolation is required to change out a 30" leaking & passing ESD Valve. We are investigating 30" x 30" mechanical hot tap fitting (s) hot tapping, & insertion of line stop(s). We are looking to achieve isolation by means of either two...
  3. bosse1950

    Piping Freeze Plug Installation Experience / Guidelines

    Gentlemen - we are guiding our client on the installation of 3 freeze plugs (1 - 30" & 2 - 24")on an existing (25+ year) offshore platform. I am looking for technical data / experience in relation to metalurgical dangers (during application & post application) which could occur during the...
  4. bosse1950

    Offshore Platform Piping Design

    I have been assigned to put together a piping class on Offshore Platform Piping Design - After 39 years in the petro chem industry I am looking for guidance in this new to me specialized field. Any input will be greatly appreciated
  5. bosse1950

    DOWNWARD WATER FLOW THRU PERFORATED PLATE

    I AM PRESENTLY DESIGNING A HYDRO COOLER WHICH REQUIRES A WATER DISTRIBUTION SYSTEM, IS THERE A CALCULATOR OR FORMULA AVAILABLE TO GIVE ME THE FOLLOWING? 1) DESIRED WATER FLOW - 10, 15, OR 20 GPM 2) WATER HEAD ABOVE PERFORATED PLATE 4" TO 5" I NEED TO CALCULATE DIA. & SPACING ON HOLES TO GIVE...
  6. bosse1950

    electrical / plc control panel design / drawing program

    I am looking for a design / drawing program for combined electrical / plc control panels, any help will be greatly appreciated
  7. bosse1950

    URGENT CFM REQUIREMENTS

    I need a calculation program for actual cfm of cooling air flow requirements for the following senario: A) desired final equipment room temperature: 75 deg.f B) overall equipment room size = 60.5ft. X 12.66ft. x 25ft. high C) overall equipment room btuh heat load = 190,683 D) external source air...
  8. bosse1950

    impingement cooling

    looking for investigative work done on impingement cooling - initial air temp.vs.velocity vs.BTU of cooling capacity, also desired airflow patterns ( full loop thru blower suction, discharge thru air cooling system to application points & return to blower suction )