  1. a10jp

    Overcurrent Protection of Utility Transformers

    At one of the job site we have, the service transformer at the utility pole is 3x 75KVA which gives 225kVA max capacity. Our contractor has previously procured a 1200A main service panel with a 1200A main circuit breaker, before he realized what the utility service will be. At 225KVA, the max...
  2. a10jp

    Neutral switching for parallel generator operation

    When you have parallel generator (emergency standby, permament installation) in operations, through a set of parallel switchgear, is there any special consideration that requires the ATS to also switch the neutral? In the case of a single emergency generator, I always prefer to solidly bond the...
  3. a10jp

    AIC Rating and Coordination of Circuit Breakers

    In the past when I did the short circuit study on the one line diagram and try to determine the AIC rating for devices, I was taught to make sure the AIC of the device can handle the fault current available at the point of my calculation. Lately, I wonder, as long as I know what the SCCR...
  4. a10jp

    Motor circuit protection

    I just want to consult others on the following. In general for motor protection(typical 3-phase motor) using circuit breakers, reading the NEC, I got: Branch ckt ground fault & overcurrent protection = not to exceed 250% FLA per Table 430.52 Disconnect device = min 115% - 125% FLA Branch ckr...
  5. a10jp

    Arc Flash and Clearances around electrical equipment

    Recently I was running into increasing the size in the electrical room and trying to account for all NEC clearances around the equipment, when a thought hit me. The equipment I was dealing are low voltage, from 208V to 480V as the highest. The thought was what about arc flash. I was merely...
  6. a10jp

    CAT 6 cables and undefloor ditribution

    Hi, has anyone heard of problems installaing premise distribution CAT 6 cables under (or within) floor slabs in open office environment? One of our customer has requested to install outside plant cables under the floor slab. His arguement anyting under the floor slab is considered exterior...
  7. a10jp

    Zero-Sequence CT and regular CT

    Does anyone know how to tell whether a currnet transformer is for zero sequence sensing and just a normal CT? For example, I am looking at the product page for one mfr. The product page did not mention anything related to zero sequence, so how do I know if it is for the particular application...
  8. a10jp

    Ground fault detection in Ungrounded System

    I am trying to understand the method to detect ground fault if you have an ungrounded system. In a few literatures I read that you will use relay 59G to sense gorunded overvoltage. Because the ground fault current in this setup is very small, they said that you will require a sensitive device...
  9. a10jp

    NEMA 4X enclosure

    Can you have ventilation openings for a NEMA 4X rated enclosure? Would that contratdict the definition of NEMA 4X, menaing splash-proof and protection against hose-down situation?
  10. a10jp

    Motor disconnect switch NEC 430.109

    Hi, as I reading NEC Sec 430.103, regarding operation of the disconnect means for motor, I was puzzled why it stated disconnect mean must be rated for the locked rotor current, in case when the motor controller fails, which has its own overcurrent protection elements. If I only have a small...
  11. a10jp

    Cable bending radius

    I have triplex cable (3 cables intertwined together) with overlal diameter = 62mm. During pulling, because of the cable run of 350m, we decided to split it ionto 2 pulls from somewhere at midpoint. The trouble is, I failed to account for the manhole at midpoint, and when the cable is inserted...
  12. a10jp

    AC vs DC Hipot Test

    If I have a cable that is 375m long, and wish to do a hi-pot test, I would imagine a DC test is more suitable because AC test would induce abnormal capacitive current across the insulation, and result in a larger leakage current. Does everyine agree with this logic? Also, is there a standard...
  13. a10jp

    manhole grounding requirement

    Just want to reassue my understanding of the requirement of bonding/grounding in manholes. My understanding is the requirement is only applicable if splicing of cables is done inside the manhole, and where the manhole is used only for pull-thru of the cable, there is no bonding requirement in...
  14. a10jp

    slab-in-grade concrete pad with precast trench

    I am not a structural engineer, but I wish to consult with others if what I have here is a problem. What I am showing (attached) is a slab in grade pad with a concrete precast u-trench section on top, and the pad is about 347" x 120". The actually rebar dimensions are D16, at 150mm (or 6”)...
  15. a10jp

    HV cable termination and cable support

    I have a question on HV able termination and want to consult others for their opinions. Being in Japan, we will have a switchgear equipment shipped from the US and where we have to terminate Japanese HV cable inside the cable entracne compartment. I am attaching a page from Schneider Elec...
  16. a10jp

    Transformer sizing for small motor loads

    Hi, this is question about sizing step-up transformer for a bunch of kitchen equipment loads that have various sizes compressors for refrigerators. These are small size compressors like 1/3 hp, 1/4hp, for ice machine, refrigerators, collers, etc. I have discussed the transformers issues under...
  17. a10jp

    Disconnects for small dry-type transformers

    I am looking for a code reference concerning dry-type transformers that are being installed inside an enclosure outside the bldg. The situation here is we have a list of kitchen equipment where the user has ordered for the wrong voltages, as such we have to provide small individual step-up dry...
  18. a10jp

    Cord and plug type motor disconnect

    Just a question on twist-lock type plug and cord assembly, are they suitable for use as motor disconnect means, for motor size 0.4kW, used for transfer pumps? I am in Japan and the catalog cuts did not specifally say motor, or HP rating. When they say "device listed for motor disconnect" what...
  19. a10jp

    Efficiency standard for Distribution Transformer

    I have a general question on efficiency on distribution transformers. In our specification, we specifiy 20000/25000kVA transformers to be factory tested to the standard of NEMA TP 1. In this case, according to the standard, which specifies the minimum efficiency levels for NEMA Class I liquid...
  20. a10jp

    4 pole switching neutral

    This is a question on 4 pole switching nuetral. In our specification we called for fusible manual transfer double throw switch rated for service equipment application, 225A, and a switching neutral. However, I have resreached several companies, they do not make any fusible switch that comes...