Search results for query: *

  • Users: dave11282
  • Content: Threads
  • Order by date
  1. dave11282

    ship supply

    hi apologies if this covered before, we have a 440v, 3 phase, 60hz supply on ship, motor control panel , using a 440v/230v transformer, to supply lighting circuit, should this the '0v' of the secondary be earthed ? ( ie wire connected from 0v to chasis of skid, control box ?) thanks
  2. dave11282

    3G router

    Hi I need a competitively priced 3G router, which can be configured for VPN, Ipsec , etc anyone recommend good quality price, is for industrial application thanks
  3. dave11282

    SLC500 to E1100

    Hi I need to connect a Bradley SLC500 to E1100 HMI, over ethernet, can anyone give me links to application notes , how to set this up thanks
  4. dave11282

    Tri rated cable hazardous area

    Hi can standard tri rated cable be used in an EExd enclosure ? think zone is zone 1 thanks
  5. dave11282

    medium voltage switch?

    hi I am trying to source a medium voltage switch, 3 pole, able to work at 3.6kv, 320mA. any ideas appreciated thanks
  6. dave11282

    Ozone detector?

    Hi all I need an ozone sensor with a 4-20mA output to PLC please can anyone recommend any UK maufactures'/suppliers thanks
  7. dave11282

    CAD Drawings?

    Hi all I am trying to source some CAD drawings for Schneider (Merlin Gerin) distribution boards Isobar 4 16 way 3phase? (I did contact Schneider, but they 'could not find any'!!) they must exist somewhere on some server somewhere, any pointers would be great thanks
  8. dave11282

    switching neutral in single phase motors?

    Hi all are they any BS standards that state that it is recommended or must switch the neutral (so the neutral is taken thru a set of n/o on the motor contactor) as well as the phase to a single phase motor 240v motor? thanks Dave
  9. dave11282

    RCD and 0.75kw motor?

    Hi all I am using a single phase TEC 0.75kw motor on 240v 50Hz UK supply. every time we drop the supply to the motor the 30mA RCD trips? I know motors can be electrically noisey, but is there a simpler way around this apart from upping the RCD to say 100mA?? Does anyone know where TEC motor...
  10. dave11282

    brass contacts?

    Hi all, we use a design where we have open face brass contacts for level switching control in a shaft, we now want to make our product suitable for external use, my concern is the possible reaction of this material and rain water, the brass switch plates/plunger carry 24v dc, are there any...
  11. dave11282

    Brass contacts?

    Hi all, we use a design where we have open face brass contacts for level switching control in a shaft, we now want to make our product suitable for external use, my concern is the possible reaction of this material and rain water, the brass switch plates/plunger carry 24v dc, are there any...