I am doing a short circuit and load flow study for a system. When I ran the ETAP software, I notoced UPS sytem can cause the voltage rise and it does little contribution to the system short circuit. is it right?
Hi, Folks,
I am running ETAP short circuit study (11kv-22KV-6.6KV-0.4KV), I ignored the most equipment impedance values, resulting in much bigger values.It is hard for me to get the data for the existing system. How can model my system in order to get the right data.By the way, S-C value I have...
Hi,
I am doing the short circuit study for an offshore project. The platform I am involed in is part of the entire system. There is another similar system about 5Km away from this platform. When I do the system study for this platform. Do I need to take that exsiting platform into...
I am conducting a system study for 6.6KV system. NGR=152
I am trying to figure out current setting of G-F relay. The formula I have is V(L-N)/152,which is 25A. I don't have a lot of experince. Is my calculation right?
I am doing a short circuit study for Middle East.But there is only ANSI comprehensive study Module available in our SKM software.I tried to change the application to IEC and 50HZ, but there are no related IEC data available in SKM liabrary.Does it really matter if I use the impedance data and...
I am doing a short circuit study for Middle East.But there is only ANSI comprehensive study Module available in our SKM software.I tried to change the application to IEC and 50HZ, but there are no related IEC data available in SKM liabrary.Does it really matter if I use the impedance data and...
I am doing short circuit studies using SKM. My understanding is the values of the positive %R. %X & % zero %R,%X are the same. But I noticed on some projects. Their zero %Z values are slightly different. Can I get the accurate data from Manufactuers?
Where I can I get the cable impedance data...
Hi,Folks,
I am still working on SKM TCC DWGs.
The Multilin Settings remains a mystery to me.
On SR-750 setting, it shows: setting1
Inst OC_PU 1.29
O/L PU 2
Ext Inverse 20
On SR469...
Hi, folks,
i am working on a project. A utility company sent me some data, which is as follows,
SR750 TD=7.3 CTR=200/5(PRI138000), Tap=2.5A inst =360A TP@5=1.84143.I need to layout this SR-750 on my 4160V(SEC) TCC. How can I do this?
Thank you in advance.
Hi, Folks,
Who knows how to compare Trans upstream curve and trans down stream curve in order to see if they co-ordinate by SKM software.
What I have is the curve from Utility side and our downstream curve in SKM.
Thank you.
Hi, Folks,
I am working on a project and I am getting into trouble coordinating with Utility Company.
My problem is, I finished our station curve plot and sent it to this Utility company.They sent back their utilty realy curve, which is SR750 50/51.It ended up overlaping with most of our...
Hi,Folks,
I have a question regarding GE relay SR-750-003.
What do Ins_OC=1.29, OC_PU=2 stand for? Ins_OC should be larger than OC_PU? Is that right?
Thank you in advance.
Hi, Folks,
I have a question regarding GE relay SR-750-003.
What do Ins_OC=1.29, OC_PU=2 stand for? Ins_OC should be larger than OC_PU? Is that right?
Thank you in advance.
Hi,
I have a question regarding GE relay SR-750-003.
What do Ins_OC=1.29, OC_PU=2 stand for? Ins_OC should be larger than OC_PU? Is that right?
Thank you in advance.