  1. swiminelectricity

    HVAC loads in offshore project

    Does anybody know what percentage of loads in the entire offshore project nomoally?
  2. swiminelectricity

    UPS contribution to system

    I am doing a short circuit and load flow study for a system. When I ran the ETAP software, I notoced UPS sytem can cause the voltage rise and it does little contribution to the system short circuit. is it right?
  3. swiminelectricity

    LV Short circuit study-

    Hi, Folks, I am running ETAP short circuit study (11kv-22KV-6.6KV-0.4KV), I ignored the most equipment impedance values, resulting in much bigger values.It is hard for me to get the data for the existing system. How can model my system in order to get the right data.By the way, S-C value I have...
  4. swiminelectricity

    UPS DC GROUNDING

    I am working on a Ups system. I am not sure if ups DC system shouldbe grounded.If needed what kind of grounding system should be used? Thank you.
  5. swiminelectricity

    exsting system Short circuit study

    Hi, I am doing the short circuit study for an offshore project. The platform I am involed in is part of the entire system. There is another similar system about 5Km away from this platform. When I do the system study for this platform. Do I need to take that exsiting platform into...
  6. swiminelectricity

    NGR sizing

    I am conducting a system study for 6.6KV system. NGR=152 I am trying to figure out current setting of G-F relay. The formula I have is V(L-N)/152,which is 25A. I don't have a lot of experince. Is my calculation right?
  7. swiminelectricity

    380V alternate line

    Hi, Folks, What does 'alternate line' stand for? Thank you advance.
  8. swiminelectricity

    Generator coupled

    Does 'all Generators coupled' mean ' they are all in service'? Thank you in advance.
  9. swiminelectricity

    IEC short circuit study by SKM

    I am doing a short circuit study for Middle East.But there is only ANSI comprehensive study Module available in our SKM software.I tried to change the application to IEC and 50HZ, but there are no related IEC data available in SKM liabrary.Does it really matter if I use the impedance data and...
  10. swiminelectricity

    IEC short circuit study

    I am doing a short circuit study for Middle East.But there is only ANSI comprehensive study Module available in our SKM software.I tried to change the application to IEC and 50HZ, but there are no related IEC data available in SKM liabrary.Does it really matter if I use the impedance data and...
  11. swiminelectricity

    Transformer and cable impedance

    I am doing short circuit studies using SKM. My understanding is the values of the positive %R. %X & % zero %R,%X are the same. But I noticed on some projects. Their zero %Z values are slightly different. Can I get the accurate data from Manufactuers? Where I can I get the cable impedance data...
  12. swiminelectricity

    GE MULTILIN RELAY

    Hi,Folks, I am still working on SKM TCC DWGs. The Multilin Settings remains a mystery to me. On SR-750 setting, it shows: setting1 Inst OC_PU 1.29 O/L PU 2 Ext Inverse 20 On SR469...
  13. swiminelectricity

    Gould strawut FUSE 32R

    Hi, Who knows how to get the information about Gould strawmut FUSE 32R? Thank you in advance.
  14. swiminelectricity

    relay superimposing on TCC

    Hi, folks, i am working on a project. A utility company sent me some data, which is as follows, SR750 TD=7.3 CTR=200/5(PRI138000), Tap=2.5A inst =360A TP@5=1.84143.I need to layout this SR-750 on my 4160V(SEC) TCC. How can I do this? Thank you in advance.
  15. swiminelectricity

    Relay Coordination programming

    Hi, Who knows if SKM software can run protective realy programming? How to do it? Thank you i advance.
  16. swiminelectricity

    Superimposing Relays curve

    Hi, Folks, Who knows how to compare Trans upstream curve and trans down stream curve in order to see if they co-ordinate by SKM software. What I have is the curve from Utility side and our downstream curve in SKM. Thank you.
  17. swiminelectricity

    Coordination with Utility

    Hi, Folks, I am working on a project and I am getting into trouble coordinating with Utility Company. My problem is, I finished our station curve plot and sent it to this Utility company.They sent back their utilty realy curve, which is SR750 50/51.It ended up overlaping with most of our...
  18. swiminelectricity

    GE relay coordination

    Hi,Folks, I have a question regarding GE relay SR-750-003. What do Ins_OC=1.29, OC_PU=2 stand for? Ins_OC should be larger than OC_PU? Is that right? Thank you in advance.
  19. swiminelectricity

    GE relay coordination

    Hi, Folks, I have a question regarding GE relay SR-750-003. What do Ins_OC=1.29, OC_PU=2 stand for? Ins_OC should be larger than OC_PU? Is that right? Thank you in advance.
  20. swiminelectricity

    SR750 MUTILIN RELAY

    Hi, I have a question regarding GE relay SR-750-003. What do Ins_OC=1.29, OC_PU=2 stand for? Ins_OC should be larger than OC_PU? Is that right? Thank you in advance.