  1. LoggerHead

    Need a driver for using Wonderware with AB device net

    I am currently using a DH 485 network to link several plc together using ABKF2 driver for our wonderware application that is communication to all of the plc's. I am needing to change over to ab device net for my plc communications and will need a different driver for the device net to...
  2. LoggerHead

    Thermocouple module causing flashing display

    I have several Powers 535 controllers controlling verious Processes using a k type thermocouple as the pv. I am needing to input these temp. signals into a AB 5,03 PLC. My plc is located close to the controllers so I just paralled the TC's over to a 1746-NT8 Thermocouple/mV Analog Input Module...
  3. LoggerHead

    Excel spread sheet help

    I have excel getting data from my wonderware program. Every time my data changes in wonderware it is updated in excel. My problem is that I have a formula in one cell to gather this data. Each time the value changes in my wonderware program it changes the value in that cell. What I am trying to...
  4. LoggerHead

    Excel spread sheet problem

    I have excel getting data from my wonderware program. Every time my data changes in wonderware it is updated in excel. My problem is that I have a formula in one cell to gather this data. Each time the value changes in my wonderware program it changes the value in that cell. What I am trying to...
  5. LoggerHead

    Using excell to collect data from wonderware?

    Wondering if anyone uses excell to gather data from wonderware instead of using wonderware to write to excell? I have been told it can be done but have not ever seen it. If I remember right, excell and wonderware can either one be the client or server. I'm no expert in excell by any means and...
  6. LoggerHead

    adding a plc to a dh 485 existing network??

    I am adding a plc 5/03 to an existing network that has 4 other plc's communication through a DH-485 communication interface. My plc's are adressed nodes 1-3, I have added a plc and it is now my first plc from the DH-485. Its the first one in the daisy chain. I thought when I added one it would...
  7. LoggerHead

    AB plc 500 with 1747-PIC

    We just got a new rugged laptop in for our electricians and I am trying to get PLC 500 dos base software to work with my PIC. The problem is that I have windows 2000 professional and they are not very compatiable. I have seen this work before using the rs linx to communicate but have been unable...