  1. NiravK

    Set Point (PAHH) for High Integrity Pressure Protection System (HIPPS)

    For one of our Projects, High Integrity Pressure Protection System (HIPPS) to be provided to protect down stream low pressure piping in case of failure of upstream Pressure Control Valve (Failure OPEN). Design Pressure at upstream of Pressure Control Valve: 63.5 Bar g Design Pressure at down...
  2. NiravK

    Critical Heat Flux - Kettle reboilers

    hello to reader, We are carrying out thermal design of De-ethaniser and De-butaniser reboilers (kettle)for one of our gas processing units using Hot oil circulation(diesel) on tube side as heating medium. I have questions about the same. What should be the maximum heat flux which i should...
  3. NiravK

    Antioxidant & Antistatic

    I want to know the chemical composition of Antioxidant / Antistatic addtivites used for 'jet fuels'. Who are the suppliers? What should an inquiry consist of, if i want to order these chemicals? What should be the criteria for the selection of these additives from available options? Thanks.
  4. NiravK

    PSV relief

    While designing relief valve, we consider 10% overpressure as a criteria, in general. What does it really mean? 1) Does this mean that the pressure in the system will remain at 110% value all the time during relief? (provided the cause of overpressure has not been mitigated). 2) Now consider...
  5. NiravK

    booster pump in cooling water

    Does anyone have an experience of providing 'booster' pump in the cooling water return line? Certain min. pressure at B/L in cooling water return line. After considering pressure drops in various exchangers, it is not possible to provide the required back pressure. So, a pump in return line is...
  6. NiravK

    Does anyone has an experience of us

    Does anyone has an experience of using sealing compounds to arrest minor leakages from flanges in high pressure process plants? how much reliable these compounds are? Thanks,
  7. NiravK

    We have the following Hyrogen compr

    We have the following Hyrogen compressors in our Diesel Hydrotreater. The op.pressure of reactor is of the range of 115 - 120 kg/cm2g. Compressor desing pressures are... [1] Make-up Gas Compressor MUGC - 2 Stage Reciprocating. With Nitrogen-> 1st STAGE :: Suction P=6.0 kg/cm2 g; Disch P=14.0...
  8. NiravK

    Start-Up Problem

    We have the following Hyrogen compressors in our Diesel Hydrotreater. The op.pressure of reactor is of the range of 115 - 120 kg/cm2g. Compressor desing pressures are... [1] Make-up Gas Compressor MUGC - 2 Stage Reciprocating. With Nitrogen-> 1st STAGE :: Suction P=6.0 kg/cm2 g; Disch P=14.0...
  9. NiravK

    We are about to carry out tightness

    We are about to carry out tightness test of a Diesel Hydrotreater reaction section for newly constructed plant. The op.pr. is 125 kg/cm2 range. To carry out tightness test of this system with NITROGEN, Make-up gas and Recycle gas compressors can provide max upto 42 kg/cm2 g pressure because of...
  10. NiravK

    We are about to carry out tightness

    We are about to carry out tightness test of a Diesel Hydrotreater reaction section for newly constructed plant. The op.pr. is 125 kg/cm2 range. To carry out tightness test of this system with NITROGEN, Make-up gas and Recycle gas compressors can provide max upto 42 kg/cm2 g pressure because of...
  11. NiravK

    Do I need to carry out Hydrotest?

    A plant in refinery is constructed before more than a year. Due to unavoidable circumstances, it could not be commissioned. All the equipment and machinery are not in operation after they are erected. Is there any standard which says about requirement of Hydrotest of heat exchanger if it is not...
  12. NiravK

    Start-up of HYDROTREATER

    We are planning for the start up of the Diesel Hydrotreater unit in refinery. The unit consist of Hydrotreater and Amine treating facility. The diesel feed is hving 2000 ppm Sulphur and the plant is designed to produce 500 ppm sulphur diesel. The problem we are going to face is the Sour gas...
  13. NiravK

    Sealing fluid for pumps

    I want to know about the criteria to select the sealing fluid required for pumps if we are considering the Plan 23 of API 610 for the centrifugal pump. Nirav Kholiya nirav-kholiya@enc.ltindia.com www.lntenc.com
  14. NiravK

    Sieve Tray Design

    I want to know if some software is available on internet regarding hydraulic design of sieve tray tower. Thanks Nirav Kholiya nirav-kholiya@enc.ltindia.com www.lntenc.com
  15. NiravK

    Sieve Tray Design

    I want to know if some software is available on internet regarding hydrulic design of Sieve tray tower. Thanks. Nirav Kholiya nirav-kholiya@enc.ltindia.com www.lntenc.com
  16. NiravK

    Design of a Chimney Tray

    I am working on hydraulic design of mass transfer columns. I want to know how chimney trays used for product draw are designed. I am interested in different aspects for this design and some reference procedure for the design. Thank you, Nirav Kholiya nirav-kholiya@enc.ltindia.com www.lntenc.com