  1. jcfoley

    IS Circuits

    As you gentlemen have been so much help in the past, I wonder if you would mind verifying my assessment regarding an IS device installation. Basically, a 4-20 mA transmitter is connected to a zener barrier and then to a PLC. The transmitter has no hazardous ratings whatsoever. An IS circuit...
  2. jcfoley

    Stress Relieving

    A colleague of mine is upset with a request of our ASME QC manager. It involves the min hold time and temperature for stress relieving a large number of pressure vessels. My colleague did the calcs and drawings with each showing the min required hold time and temperature for each vessel. Each...
  3. jcfoley

    NEC 500 & Nonincendive Wiring

    Is nonincendive wiring required to be separated from other circuits like IS wiring? I have seen a reference supporting that this separation is required but I cannot locate it. It very well could have been a "recommended practice" from a customer or a manufacturer. Does anyone know of a NEC...
  4. jcfoley

    Conduit Grounding/Bonding in CLI, DIV 2

    I hope you folks can help me out here. I am a mechanical engineer but have had to deal with controls for quite a few years. I now have an electrical PE pounding me for information on grounding/bonding practices. I have seen this done several different ways. I know that NEC requires equipment...
  5. jcfoley

    Piping Acoustical Vibration

    Does anyone know of good training resource for acoustical piping vibration? This seems to be a very specialized subject with very little real information on the web. I have GMRC's Pulsation & Vibration Short Course but I am looking for others. Thanks, Chris Foley Midland, TX
  6. jcfoley

    Nozzle Loads

    I know that I may be searching for a non-existent answer, but I have to ask. In lieu of a customer’s specification for a nozzle load, what should a vessel supplier use for this calculation? It has been a practice for some suppliers to use nothing. I think that this is a just ignoring the...
  7. jcfoley

    IS Device Question

    I have an application for an oil flow meter in a Class I, Div II, Grp D envirnoment. We have always used a REN Slow Flow meter for this lube oil measuring task. However, this meter has no electrical approvals at all. I am told by the manufacturer that it can be used in hazardous locations...
  8. jcfoley

    ISA Tag for a PLC

    This a follow post to my "P&ID Symbology" last week. I have worked through ISA S5.1 and created the tags for my instruments with one major exception. I do not see what tag should be used for a PLC. I have used YC for an annunciator as it is really just a state controller. A plc is quite...
  9. jcfoley

    P&ID Symbology

    **I apologize upfront as this is a cross post. I placed it ISA Controls forum but have not seen many responses. *** I have been in the equipment industry (compressors mainly) for the past 11 years. I have seen more combinations of symbols used on P&ID that I really care to. However, I have...
  10. jcfoley

    P&ID Symbology

    I have been in the equipment industry (compressors mainly) for the past 11 years. I have seen more combinations of symbols used on P&ID that I really care to. However, I have been asked to write a company standard. I sort of thought that ISA-5 would contain everything that I needed to know...