Hello all,
I'm using using Caesar II to model the piping system with the use of tied-rod expansion joint to reduce forces and moments excert on equipment nozzle. The joint was modeled per Caesar II application page 5-6 with restraints RX, RZ, and rigid Y.
The system designed to allow the...
Hello Everyone,
Has anyone done the Modal analysis with Caesar II? I have a steam piping system experiencing of vibration problem and attemp to run modal analysis with Caesar II, but don't know where to start. I appreciate if someone can help how to set up the control parameter and determine if...
A steam line design condition at T=1050 F, P=1340 psig. Is it practical to have stop valve a flange connection instead of butt weld? What is a major concern if the flange connection being used from the stress point of view? Your input is appreciated.
Regards
I'm searching the allowable stress at elevated temperature for ASTM designation A523. ASME II-D is not listed. I do found the Yield strength at room temperature. Any help to find this info is appreciated.
Regards,