Gents,
I have a reduced crude vacuum transfer line (700F) subject to localized napthenic acid attack. Metallurgy on the line is 5CR (A335 GR P5). One of our options is to upgrade a number of small-bore connections (thermowells, vents, etc.) and L.R. ells to 317L. Could someone provide general...