Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: sunloco
  • Content: Threads
  • Order by date
  1. sunloco

    Bleed ring for temp. detection use

    Forgive me for my general question. Because some special trouble I can't drill on the pump casing for temperature detection. someone advise me to use a bleed ring with RTD to detect. Does anyone have experience on bleed ring with RTD for temp.detect? where to install bleed ring, how to install...
  2. sunloco

    rubber for beer vessel

    Sorry ,I don't know where i should post this topic,so I found the material section. I met some question, any one can help look at the drawings, what material is for this beer vessel and how to adhere this material with the stainless steel vessel. below is link...
  3. sunloco

    warm up for chemical process pump

    who can explain clearly warm up for chemical process pump? In many case like pumping Aromatic Hydrocarbon need warm up before start? any one knows ? why need warm up ? how to warm up ?the piping or capacity ,temperature ?
  4. sunloco

    pump reserve rotation rate

    I would ask you a question about our double suction pump , I didn’t understand one term ,I feel it is diffcult to explain clearly. we first call it : pump reverse rotation rate . In my point this rate means relation between pump reverse rotation speed and pump regular speed .when pump is...
  5. sunloco

    what is inertia capacity of pump ?

    as captioned
  6. sunloco

    who knows where can find API piping plans introduction

    as captioned .who knows ,please give me a web link
  7. sunloco

    Non overloading power V.S Runout power

    Anyone can give a specific explanation for this two glossary in the pump curve, in my view I think the same meaning sometimes. but in certain curve data it will mark non overloading power at certain capacity ,not maximum capacity of rated impeller diameter. that's confused.
  8. sunloco

    Impeller damage

    Hi Buddies, we visited a water &sewage water co. The factory includes an inlet pump station and an out pump station. There are 6 split case pumps in each pump station. The customer told us that the first 4 pumps of each pump station were all damaged at the shroud of the lead edge, They had...
  9. sunloco

    pump casing leakage hole

    http://photo.163.com/photos/sunloco/67009346/ Please see the link about the pics of pump casing. This is seconde casing of in-line pump that was damaged.we could find any problem for medium or structure failure. in the casing near to casing wear ring there is obvious abrasion ,especially there...
  10. sunloco

    high pressure Pump for seawater reverse osmosis

    Anyone know which kind of pump is for seawater reverse osmosis? the specification is Capacity : 1315 T/H, 75 bar. Nomally we use reciprocating pump for RO. but this capacity is terrible. Any comment and advise is appricated .
  11. sunloco

    How to calculate BHP of reciprocating pump

    How to calculate BHP of reciprocating pump ? Any guy can give a formula or info?
  12. sunloco

    variable frequency drive and and standard epact motor

    In many building cases we supplied HVAC pumps with standard motor though it will be controlled with frequency inverter ,Normally I use standard epact motor to meet variable frequency needs,but I want to know what variable range is frequency for standard normal motor ? and under what situation...
  13. sunloco

    how to cooling split case pump

    Single stage split case pump basically pump water in normal temperature, but if we use it to pump water in 120 centigrade,how should we cool this pump ? cooling bearing and mechnical seal ?Is there any drawing available in website ?
  14. sunloco

    Electric drive fire pump

    I saw a selection table about electric drive fire pump (FM approved ,U.L. listed) In this table I found that BHP of most fire pump is higher than electric motor HP. for example : capacity :500GPM,rated pressure :210Psi, the BHP(brake Horsepower) is 112 HP, the electric motor fitted is only 100...
  15. sunloco

    175hp motor ?

    Is there 175hp e-motor in standard power range? In IEC standard I see there is 132Kw E-motor,but in NEMA standard it seems only 150hp and 200 HP? any one kindly enlightens me a little
  16. sunloco

    service factor of motor

    I often see the service factor of motor when I select e-motor , but I don't know the exact meaning of service factor,I often see factor 1.1 and 1.0 , Could any one explain what is service factor and what do we need to pay attention to when we select factor ?
  17. sunloco

    start-up methods

    I saw many start-up methods : Across the line ; Part winding; Wye-delta open;Wye-delta closed ; Primary transformer ;Auto Transformer; Solid state; Who can tell me under what conditions I need to use the corresponding start-up methods ?
  18. sunloco

    service fator of motor

    I often see the service factor of motor when I select e-motor , but I don't know the exact meaning of service factor,I often see factor 1.1 and 1.0 , Could any one explain what is service factor and what do we need to pay attention to when we select factor ?
  19. sunloco

    Jet pump and turbine pump

    hi,buddies ,I am a chinese,In our manual there are not category to be called jet pump or turbine pump. so I don't know to understand this two kinds of pump clearly. Do these two kinds of pumps still belong to centrifugal pumps ? or others ?
  20. sunloco

    motor protect proof

    In NEMA standard normally use ODP and TEFC enclosure. but in IEC standard we often use IP54.IP55 and so on so who knows how to compare these two kind of standard ? somebody told me that TEFC approximatelly equals to IP54. Is it right ???