Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: bjeservice
  • Content: Threads
  • Order by date
  1. bjeservice

    St 52-3 duct

    Hi i need to know if the steel (St 52-3) is suitable to build a duct working at (400 degree C) for the cement factory. could any one tell me which mechanical proerties affect the thermal ducts design. any ref.,links, files would be so appreciated. thanks
  2. bjeservice

    high voltage power supply diodes

    hi i need to know the types of rectifier diodes and rectification methodes suitable for obtaining a dc power of 110kv at 1 amp. suitable for supplying the electrostatic precipitator of cement factory best regards
  3. bjeservice

    precipitator cable

    hi i need to know why is the precipitator cable cross section area used in cement factory = 70 sq.mm although its average dc current < 1 amp. Also i need to know why it is generally be Copper and not Aluminum cable. any information or link will be appreciated
  4. bjeservice

    silicon steel specific heat

    hi i need to know exactly the specific heat of silicon steel used in building the transformer cores. is it same as the (iron/steel) specific heat that is ( 452 J/Kg/K ) thank you
  5. bjeservice

    pt limit output VA meaning

    i need to know what is the meaning of ( limit output=200VA ) written on the name plate of a potential transfomer of 6600/100 volt ratio, with a rated output of ( 30 VA ) this pt is single phase class=0.5 transformer.
  6. bjeservice

    potential transformer class

    hi i need to know whats the meaning of class ( 6p ) that i found in the name plate of a potential transformer of two secondary windings ( first coil class is 0.5 ) and the pt is made in China. where could i find any detailed information about this please thank you
  7. bjeservice

    power resistor temperature?

    i built 0.1 ohm power resistor in order to use it in induction furnace start cct. the current that must pass throught is: 1000 amper for one second. could any one help me finding an equation that connect the temperature with time for the resistor. for more details the resistor width is 60 mm ...
  8. bjeservice

    current transformer problem

    Dear friends i tried to built an electronic control circuit for earth fault protection, so i built a current transformer with the information listed below ( as i know some informations of how to built them ). the current transformer load is 200 ohm resistive, the voltage that i need to deal with...
  9. bjeservice

    class x current transformer

    hi could any one gives me any informations (or any link ) on how to design a class x current transformer . thanks