  1. lzh007

    Is smoke exhaust fan required in 2 story atrium?

    For a 2 story and 12 meter high atrium in a health care facility, should we put smoke exhaust fan on top?
  2. lzh007

    Cooling load of X-ray machine

    For a general radiography suit in a hospital, how do we guess the cooling load of the X-ray machine. The input is 150 KVA, output 80 kW, What's the percentage is appropriate for calculation? On the ASHRAE handbook, the table shows average load corresponding to nameplate load. It does not make...
  3. lzh007

    Is it allowed to use VAV in health care facility?

    I saw some hospital project using VAV to control temperature, I am not sure if it is allowed by code and how to guarantee the pressure relationship between different zones if so. THX
  4. lzh007

    About fire extinguisher in crawl space

    Do we need to put fire extinghuishers in crawl space according to NFPA? it is only about 1 meter high inside. I think it is impossible for people running to get fire extinguisher in emergency.
  5. lzh007

    What's the pressure needed for VAV box?

    We used to connect VAV to medium velocity system. Can it be used in normal low speed duct system?
  6. lzh007

    Question about glycol heating media

    For the convector and radiant panel, if the mean media temperature is the same, is the output of water and 50% glycol same?
  7. lzh007

    About Leed workshop and test

    How much will LEED workshop help the test? Any big difference between Canadian and US test?
  8. lzh007

    About the return air of VAV system

    if there are lots of VAV box at the supply terminal, how to design the return duct? There will be a return fan because return ducts reach to each room.
  9. lzh007

    About selection of return grille

    When select return grille, what's the rule to follow. Someone says the speed should be kept under 500 fpm. While according to some product catalogue, if using the lowest NC level to select, the speed can be 800 fpm or even higher. I am a little confused. The reason to keep the speed is to...
  10. lzh007

    About the mechanical room

    Under which condition should the wall of mechanical room be fire rated? I heard somebody said the building is bigger than 400 m2. Right?
  11. lzh007

    about the paint booth exhaust

    How to decide the exhaust air flow for a paint booth hood? What kind of exhaust fan is typically used? The ASHRAE mentions the ACGIH. What's that?
  12. lzh007

    selection of water heater

    Normally for apartment building, should we select water tank for a domestic water heater? (for example there are 70 suits inside) As I read in Ashrae handbook, 2 data are used to select heater and tank, recovery rate GPH and size of storage capacity Galon. While my boss always selects a heater...
  13. lzh007

    Question about the selection of domestic weater heater

    Normally for apartment building, should we select water tank for a domestic water heater? (for example there are 70 suits inside) As I read in Ashrae handbook, 2 data are used to select heater and tank, recovery rate GPH and size of storage capacity Galon. While my boss always selects a heater...
  14. lzh007

    question about the TJ joist in wood apartment

    Normally we put all duct in bulkhead along the wall in apartment building. I know it looks ugly if the ceiling is not high, but it will comply with the fire requirement. While sometimes the owner request to put duct in the joist space. My boss seems not willing but accepts whatever. I want to...
  15. lzh007

    question about the direc fired make up air unit

    where can we use direc fired make up air unit? Somebody told me it is for any ventilation purpose as long as no one sleep in the conditioned area, such as restaurant and office. Direct fired unit makes me a little uneasy, is it really safe for people inside?
  16. lzh007

    Question about the industrial building pressurization

    Normally when should we consider to provide pressurization for industrial buildings and how to decide the Min outside air? I am in Canada. I can not find this information in local building code.