  1. TestBeforeTouch

    Delta Connected Capacitor Bank

    I am installing an electronic trip unit on a 480 volt Circuit Breaker that is protecting a 240 KVAR capacitor bank. The cap bank is made up of 12 modules. Each 20KVAR module consists of 3 delta connected capacitors (each cap is 6.66 KVAR). The substation is a typical 1500KVA solidly grounded...
  2. TestBeforeTouch

    Restarting a coasting motor

    How long do you need to wait to restart an induction motor that is still coasting? I have a 1000HP 4160V motor for a large blower that will coast for 10+ minutes after it is shutdown. In this case, if the motor is off for more than 5 minutes the plant must go through a very lengthy startup...
  3. TestBeforeTouch

    European motor nameplate values

    A 750KW, 4000V European motor at my plantsite in the US lists three parameters that I am not familiar with and I have not been able to find a reference on: Ma/Mn = .7 Ia/In = 5.3 Te = 16s The Ia/In looks like the ratio of locked rotor current to full load current (maybe Iaccel./Inormal) but I...
  4. TestBeforeTouch

    Greater than LRA on starting due to unbalance

    Is it possible to draw greater than LRA on starting due to a voltage unbalance caused by a bad connection? This weekend a 1000HP 4160volt motor with a normal 12 second acceleration time tripped two of its 3 mechanical overloads in 5 seconds during a start. The installation was checked and a...
  5. TestBeforeTouch

    Could Vacuum Contactor cause motor failure?

    About a month ago I replaced an old 2300 volt oil immersed motor starter lineup with new vacuum contactor starters. One of the motors has since failed to ground and I was wondering if the failure could have occurred because of a transient caused by the fast interrupting time of the vacuum...
  6. TestBeforeTouch

    Ultrasonic detectors for 15KV PM

    Does anyone have any experiance (good or bad) using an ultrasonic detector as part of a PM program on 15KV class distribution equipment.
  7. TestBeforeTouch

    Sizing Core Balance CT's

    I am looking for some advice or a reference on how to size a Core Balance CT for differential protection for a 2500HP 6900 volt motor. The motor is 190 FLA. I have been told I should use a 300:5 CT by one person and 50:5 by another. The system is high resistance grounded.
  8. TestBeforeTouch

    Silicon Bronze Alloys

    I am an Electrical Engineer looking for some information on the advantages and disadvantages of the different types of silicon bronze alloys for joining bus bars together. I know that Silicon bronze is a general term that describes various types of copper-silicon alloys manufactured under...
  9. TestBeforeTouch

    Silicon Bronze Bolts

    Does anybody have any experiance in selecting between the different types of silicon bronze hardware for joining busbars? I know that Silicon bronze is a general term that describes various types of copper-silicon alloys manufactured under trade names such as Everdur, Herculoy, Duronze." The...
  10. TestBeforeTouch

    Volts Squared Hours meter

    What is the purpose of a volts squared hours meter? My utility company has one installed on my purchased power substation but I can't find anyone who knows what it is for.