Trying to measure the discharge flow from a steam jet ejector. The motive steam is superheated, suction is off of a vessel of boiling water, and I'm told that many attempts to measure the discharge steam flow have failed due to it possibly having water droplets. A vendor of a V-Cone meter told...
Folks,