  1. giuseppe

    Tunable Luminaires for full Circadian Rhythms

    I am due to design a full Circadian Rhythms Illumination System within a Human Behaviour and Sleep Disorders Researching Center in UK, and I have been tasked the duty to investigate the market for a full spectrum Driver / LED / Luminaire that would offer a continuous tuning of the spectrum from...
  2. giuseppe

    Load of three two-phases resistances

    Hi to all. I have a question that maybe simple for some of you guys. I have to supply a transformer with a cable (primary) sized for three loads (secondary) of 150KVA two-phases resistances @ 400Vac phase-to-phase. What will be the resulting, effective load on the Primary, as to size the...
  3. giuseppe

    Circuit breakers: 3ph VS 1ph

    Hi to all. I have a simple question that may have a complicated answer: when testing a three phase Circuit Breaker with a single phase Current Injector, what will happen if the test is carried out only on one pole (line-in/line-out). I am presently far away from a laboratory and I cannot carry...
  4. giuseppe

    RTD cables

    Hi to all. I am presently involved in a project where lot of RTD's (Resistance Thermal Devices) are installed on field equipment, particularly on transformers and electrical motors windings. As I am preparing the Cable List for the whole field, is there any specific requirement for the cables...
  5. giuseppe

    Current Tranformers secondary earthing

    Hi to all. I have an issue on the earthing (or grounding) at the secondary of Current transformers. Generally speaking, the Primary of a Current Transformer is marked P1 and P2, with P1 normally being positioned where the Current enter the Transformer and P2 at the exit. Accordingly, S1 (or...
  6. giuseppe

    British Standards Graphic Symbols

    Hello there. Is anybody aware of the latest Graphic Symbols for Schematic Diagrams and drawings from the British Standards? I looked in several Standards Libraries but I cannot find the relevant Standard Number. I would just need the Standard Number (current one) or the proper denomination...
  7. giuseppe

    How to calculate the Heat within a Panelboard

    Hi to all. I wonder if anyone there has a "rule of thumb" to calculate the Heat generated by a Panelboard. I can't remember the formulas and I am presently out of books reach...! Thanks to whomever wishes to help. Giuseppe