Hi All,
Have a 160 MW steam turbine that has been exposed to steam contaminated with seawater. Am interested in advice for how to sample and analyse salt deposits on the turbine and the typical limits for salt levels on turbines to determine whether cleaning is necessary. Any help would be...
We have had a failure on our plant. In order to restart we have had to replace an elbow in a 150 NB CL 150 epoxy piping run, with a SS316 elbow with carbon steels flanges. The pipeline holds relatively stagnant seawater in a vacuum line.
I would like to improvise a cathodic protection system...
We run a bitumen blowing tower producing emissions of dioxins and PAH's, which we exhaust to an incinerator.
The incinerator is reaching retirement and we are looking at employing worlds best practice to remove the toxic compunds from the blowing tower exhaust. Is there best thing to do to build...
I have just started work on a project to install bitumen splitter from imported bitumen flux. Can anyone who operates one please provide with a rundown on how they work ?
Our refinery is searching for an online automated instrument to measure viscosity of its vacuum residue used for bitumen manufacture. We would preferably measure the viscosity straight off the Vacuum distillation column however the temperature at this measurement point would be around 400 deg C...
We have some aluminium clamps on some water cooled cables which carry electrical energy from a 200 MW generator to a transformer for distribution.
There is a white crystalline substance that has formed on the clamps, it appears to be a fine threaded substance resembling spider web rolled into...
I run a gas turbine compressor station on a large gas pipeline. The lube oil on the gas tubines on two stations have gone black in colour. The oil checks out otherwise, regarding every component of it's specification, temperature has bone monitored and particle count checks out. We would like to...
I have a filter constructed from SS316L. It has experienced severe pitting around the sealing faces above and below the gasket.
How can I alleviate the situation to reduce the rate of pitting ? Should coatings be used or cathodic protection ?
What is the best way to rebuild the face of the...
I am a team member managing a gas turbine plant of around 500 MW and have recently had a fogging system installed and associated 1000 ton tank for water storage. We only plan to run the fogging during peak periods and store the water for use as required. The OEM has stated that we must drain the...
We have alot of boiler tube left over from commissioning of our HRSG and would like to preserve it for use in the future. Does anyone have any advise about what is the best method to do this ?