Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: broncosfan
  • Content: Threads
  • Order by date
  1. broncosfan

    over my head

    I work for a large engineering firm. I've been there for about 5 years. I am licensed and normally work on warehouse type structures. I'm in my early 30's. I was recently asked to get licensed in another state for an upcoming project. I agreed not knowing much about the project. We are...
  2. broncosfan

    wave action?

    I am working on the design of a steel manufacturing building in mobile, alabama. It's on the coast. One statement that I came across is, "The current site is located in a Zone VE (elev 12), which is a Coastal Flood with Velocity Hazard (wave action) with a base flood elevation determined."...
  3. broncosfan

    self tapping screws thru gyp board

    I have a pump room with a ceiling framed of light gage metal studs and 2 layers of gyp board on the bottom. The mechanical guys are running a 6" pipe below the ceiling. The ceiling is a one hour rated assembly. Can I use a self tapping screw in this situation through the gyp board and into...
  4. broncosfan

    round concrete column

    Is there a limitation on the spacing of the vertical reinforcing around the perimeter of a round concrete column. With round ties, is it to be limited to 6" per ACI 318? Or do round ties let me go further than 6"?
  5. broncosfan

    concrete mix

    I am looking a set of structural drawings from 1918. The concrete mix is called out as 1:1:2 and 1:2:4. Does anybody know what this means? What would be the corresponding strengths of concrete?
  6. broncosfan

    "ductile failure" of anchor bolts

    I am designing a base plate of a special concentrically based frame. I understand that it is preferable to maintain a ductile failure mode. Does this just mean that the strength of the concrete embedment needs to be greater that the steel strength of the anchor bolts? Currently, I have 1 3/8"...
  7. broncosfan

    collector design

    I have a steel framed building with braced frames. On the frame lines, I have wide flange girders supporting joists spaced at 6' o.c. The wide flange girders are acting as collectors and support an axial force. Looking at the weak axis of these wide flange collectors in compression, what...
  8. broncosfan

    ponding

    Hi AISC has two design procedures for ponding. One is for a case where there are flexible primary and secondary members. The other is for when there are flexible secondary members bearing on a wall (infinitely stiff primary member: Cp=0) What happens if you have roof joists bearing on a...
  9. broncosfan

    special concentric braced frames

    Hi, I understand that the brace connections for an scbf need to be designed for the expected strength of the member. At the pier and foundation, the brace gusset plate is attached to the column and base plate. Does the base plate attachment to the pier and footing need to be designed to...
  10. broncosfan

    building separation

    I am trying to calculate a required building separation per ASCE 7. For the special concentric braced frames, the deflection amplification factor is 5.0. For the building movement, I am adding the deflection of the braced frames plus the deflection of the diaphragm. The amplification factor...
  11. broncosfan

    SCBF question

    I am designing a 70'-6" high by 16'-1" wide special concentrically braced frame in the state of washington. I went with a SCBF because of the height of the warehouse. The frame supports an earthquake force of 25.0kip at the top. The dead and live loads are small. I have two columns and I...
  12. broncosfan

    wind exposure

    What's the correct way to determine the wind exposure category of a building? The building code seems vague (big surprise). Other engineers in my office usually just design the building for exposure B. But I don't see anyone going out to the building site with a tape measure and walking 2600'...
  13. broncosfan

    tilt wall base fixity

    I am using ENERCALC to design some tilt walls. ENERCALC lets the engineer select the ACI 318-02 procedure. Under this analysis procedure, you can select a base fixity for the tilt panel. How do you determine the amount of fixity at the base of the panel? The program let's you select a fixity...
  14. broncosfan

    roof uplift

    I am designing a building in a hurricane area. The wind speed is about 130mph. The building is a large warehouse with numerous dock doors. These dock doors make it partially enclosed. I get a component and cladding wind uplift of 51.3psf on the joists. Is this force reasonable? I was told...
  15. broncosfan

    sloped bond beam

    We called out a continuous reinforced masonry bond beam near a roof. The roof elevation slopes. The bond beam is acting as a chord. Is it common for the bond beam to slope with the roof? Is this easy for contractors? How is this done since blocking is in 8" increments? Would it just be...
  16. broncosfan

    foundation design - need quick answer

    This question is probably answerable by someone familar with bridge design, but the AREMA design manual for train structures indicates that impact loads are not normally considered for foundation design. Does that include reinforcement or are they just referring to stability issues (such as...
  17. broncosfan

    california tilt wall

    For a concrete tilt wall building with a metal roof deck and joist framing, we would typically support the joist seats on 8"x6"x5/8"(LLV)x12" long seat angles welded to a steel embed. We would then run a continuous 4"x3"x1/4"(LLH) along the wall and weld it down to the top of the joists and...
  18. broncosfan

    cover plates

    I need to reinforce some wide flange girders and columns with cover plates welded to the flanges. I am welding the cover plates to the flanges with a 1/4" fillet, 3" long, spaced at 12" o.c.. I did this because I've seen this "skip" weld called out elsewhere. But how do you check if that weld...
  19. broncosfan

    cantilevered roof girders

    I am looking at 30 year old roof. The framing consists of joists at 6' on center, supported by wide flange girders. The wide flange girders are cantilevered over the columns varying distances and spliced, I guess to save weight. I've looked at it with enercalc and can't get any of the girders...
  20. broncosfan

    masonry diaphragm aspect ratio

    We are adding a 90' long x 25' wide connector between two warehouses. There will be two 90' long, 12" thick reinforced masonry walls. The roof will consist of 25' long joists spaced at 6' on center with 18ga type B metal roof deck. The 18ga metal roof deck will be tied into the precast...

Part and Inventory Search