  1. supaman79

    Chilled Water Line near electrical panel

    Guys, I have a 2-1/2" Chilled Water line penetrating a basement foundation directly beneath a eletrical panel. Are there any minimum distances, or precautionary measures i should take to do this. If so or not, what codes could i got to help me out with this? BOCA? NFPA?
  2. supaman79

    Chilled Water Lines near Electrical Panels

    Guys, I have a 2-1/2" Chilled Water main penetrating a basement foundation that will be located directly underneath an electrical panel, will this be a code issue? And if so or not, will BOCA of NFPA touch this issue?
  3. supaman79

    inserting a.tif file in acad 2005lt

    does anyone know how to insert a .tif file into 2005lt????
  4. supaman79

    Water Room (Autoclave) & Chemical Storage Design Criteria

    Does anyone know where I can get some design criteria for an Autoclave room and also a chemical storage room other than ASHRAE. From past experience I know some paremeters vaguely, but it's been a while. I need to know exhaust requirements, filtration, pressurization, blade material (spark...
  5. supaman79

    Sch. 40 PVC thru a fire-rated floor

    Guys, Do you have any input on how to fire protect sch. 40 pvc pipe passing thru a fire-rated floor. Is there a minimum gauge sleeve I need to use?
  6. supaman79

    Zone Damper & Bypass Damper for 3,500+ CFM

    Guys, Does anyone know of a zone & bypass damper that is capable of handling 3,500+ CFM. Trane VADA's only are capable of of providing up to 2,500 CFM. Also, it needs to be capable of communicating w/ a packaged gas/elec. Trane RTU...any input?
  7. supaman79

    Ventilation Rate for Intermittent Spaces (lecture rm.)

    Guys, I was told per the IMC Appendix A, it would tell me that I'm only required to supply half the outside air to the space if it was only occupied for 3 hrs. or less. 1.) Is this correct? 2.) When I went to the Appendix A, It talked about combustion air and clearances...where is this code...
  8. supaman79

    Gas Piping Thru Interior Walls

    Guys, Can I run a natural gas line thru interior walls, and if so are there any specific requirements that I need to meet in case of demo. work being done in the future.
  9. supaman79

    Plastic/Black Steel Supply Grilles Manufacturers

    Does anyone know of any Plastic or Black Steel R,G,D Manufacturers?
  10. supaman79

    Underground Chilled Water Piping

    Guys, Does anyone have experience with underground piping for a cloed-loop chilled water system for a residential house? I plan on using a 3" PVC supply line to the house (500 ft to the house)....some questions pop into my mind like.. 1.) How do you penetrate to the ground? Bracing or...
  11. supaman79

    Dehumidifying a Residential Basement

    Guys, As some of you might know already, I'm knew to the HVAC/R trade, and I've come across a simple problem for you guru's (haha). A residential building (near the shore)that I've been working on needs dehumidification in the basement. Our ductwork is already sweating, since we haven't...
  12. supaman79

    Ventilation for High Occupancy Areas

    Guys, When ventilating a high occupancy area such as a cafeteria or lunch room...how much can I reduce to per Mass. Energy Codes. The energy code specifies that I have to reduce to the spaces minimum per the Mechanical Code Appendix A. But within Appendix A I can't find the minimum...
  13. supaman79

    Layer Pull-down Menus in ACAD 2005LT

    Guys, I just installed autocad 2005lt on my computer, everything is running great except the layer pull-down menu. It takes forever for the pull-down menu to come down so I can freeze, thaw, or change layers etc. Is this a RAM problem, LT bug. I still have the old ACAD on my computer, maybe...
  14. supaman79

    Capture Velocity For Type II Hoods

    Guys, I'm redesigning a ventilation system for a type II hood (bread only, non-portable unit). Originally an engineering firm designed a national system for Subway that absolutely did not work, so Subway hired us to redesign it to remove the bread odor and heat generated from the equipment...
  15. supaman79

    Pump Head

    Guys, When calculating the pump head on a closed chilled water closed loop....should I add all my pressure drops for my chilled water coils, or just my largest P.D.. I would assume just my largest, having that they're not in series. Can anyone help? Thanx
  16. supaman79

    Primary/Secondary Piping Arrangement

    Guys, This might be a simple physics question, but here it goes. On a primary/secondary piping system, physically how big does the primary loop have to be. What pops out at me right away is that, I would assume that you would need to have enough water in the primary loop to heat the secondary...
  17. supaman79

    Avg. BTU Rating for Appliances (Microwaves, Refrigerators, Etc.)

    Does anyone know where I can find an avg. BTU rating for refrigerators to apply to my cooling loads? I've looked in the ASHRAE handbooks, but I can't seem to find anything.
  18. supaman79

    Max. Air Change Rates for Animal Hospital!!!

    Guys, I have some Misc. rooms in an animal hospital that were questioned by my boss if we need the amount of air changes/hr that the GC requested. Currently we have an animal ward room that was requested to have 8.5 ac/hr......x-ray & surgery rms @ 7.1 ac/hr...etc. Does the International...
  19. supaman79

    Converting NC rating to DB

    Can anyone tell me how to convert an NC Rating of 35 to db (decibals)
  20. supaman79

    Location of Flow Switch in a Chilled Water Closed Loop

    Guys, What is the proper location for a flow switch? Is it in the return or supply side of the chiller?