  1. Colinjohnson

    Sizing a neutral earthing breaker

    Gents, Best practice would suggest that a DG Neutral Earthing Breaker would be sized as the Phase circuit breaker but is this really necessary given the low neutral current which will flow in service ? Are there any factors which would justify derating the device and what might be a sensible...
  2. Colinjohnson

    UK embedded generator neutral earthing

    Hello, I am designing a power system which comprises a 11/0.4kV 1000kVA grid connected transformer feeding an LV switchboard. In addition a 1000kVA generator will be used in parallel with the transformer for occaisional peak lopping (TRIAD operation). To meet the requirements of G59 and in...
  3. Colinjohnson

    Earthing or Grounding

    Hello, I work in the water industry where the standard earth nest resistance for an LV transformer is usually specified as 1 ohm. We have a site which where the ground conditions make it very difficult to get anywhere near that figure which has prompted a debate about where the requirement for...
  4. Colinjohnson

    Sizing duirect buried cables

    Gentlemen, How would you size this particular cable ? Service - 400V AC 50HZ TPN Load 1666A Power factor .91 Cable:- Single core XLPE AWA armour to BS5467 laid up in trefoil. Installation - Direct buried in soil at 500mm below surface groups spaced 600mm apart I have referred this to Pirelli...
  5. Colinjohnson

    Trefoil cable installation

    Could anyone advise why power cables are arranged in trefoil groups ? I suspect it is to negate induced or circulating currents but are there any publications which deal with the subject ?
  6. Colinjohnson

    Determination of harmonics during design process

    Gentlemen (and ladies), Is there a rule of thumb for approximating the triplen harmonics which are produced by IT and other equipment which would assist in calculating transformer size during the design process ? In the UK the normal power system within a commercial building will comprise a...
  7. Colinjohnson

    Loss of neutral in star connected system

    Gentlemen (and ladies), I would be grateful if you could help me to ascertain the phase to phase voltages which will result within a three phase star connected network should the neutral conductor become disconnected from the star point of the transformer. This occurred in a hospital recently...