  1. kh2

    The determination of the number of slots in a synchronous generator

    The project is to upgrade a hydro synchronous generator 50 MVA, 24 poles, 3-phase wye, 13.8 kV L-L, lap winding, 2-turn/coil, 2-circuits, 198 slots. The upgrade shall include the rewind and to replace the stator core. The new rating shall be 60 MVA. The alternatives for the rewind are one turn...
  2. kh2

    What is the min. striking distance between energized parts and covers?

    This question came up during the rewind of a 13.8 kV machine 40 MVA, Hydro. The new bars were elongated by about 6 inches. As a result the air baffles (covers) became closer to the overhang portion of the bars which reduced the clearance between the live parts and the covers. The Contractor...
  3. kh2

    What is the min striking distance for a 13.8 kV generator winding?

    In the rewinding and uprate of a 40 MVA (uprate to 46 MVA), 13.8 kV, 3-phase, 60 hz, one circuit, wave winding, hydro generator, the mean length turn has increased to achieve bar end arm and cross over clearances of 1/2". This resulted that the overhang portion of the bars (winding) was...
  4. kh2

    Platinum vers Copper RTDs for stator temperature detection

    This subject is about the practice of using six wire dual element RTDs, copper (10 ohms) and platinum (100 ohms) Resistance Temperature Detectors (RTDs) placed at two different axial locations in the stator slots between the top and bottom bars. The new trend is to use only platinum because of...
  5. kh2

    What is the size of the series connector compared to the coil size?

    The series connectors are the parts that connect, in series, two coils by brazing them between (or inside)the connectors. This practice is used on the stator coil winding connections. The series connectors are carrying the same amount of current as the coils. Therefore, it is assumed to be sized...
  6. kh2

    Minimum spacing between bar end arms and crossover clearance.

    This subject is about the minimum spacing between the bar end arms and the minimum clearance at the first crossover bar behind the top bar on a 13.8 kV rotating machine, 3 phase wye connection, NEMA Class F insulation, air cooled hydro generator. Some specifications for the stator rewind asked...
  7. kh2

    Sizing the generator-set for the core loop test.

    How do you size a three phase 480 volt gen-set in KVA (KW) based on loading only one phase of the gen-set? The current required to perform the core loop test (in this case) is 615 amps single phase at 480 volts. Appreciate your expertize and valuable responses.
  8. kh2

    Differential Relay Operation.

    Does the Differential Relay operate with zero current from on side and no internal fault? Three single phase Generator/Transformer differential relays with percentage and harmonic restraint. They are GE model 12BDD15B relays. Tap setting is 2.9 Amp, zero restraint pickup 0.87 amps, 25% slope...