  1. Atooz

    Lateral Shaft Capacity

    Trying to design a drilled shaft which has high moment (1200 kip-in) and axial load of 10 kips. The steel column on top is concentric to the shaft. But e =M/P = 120 in which is too high. Trying to use column interaction curve ACI c4-60.6 and C4-60.7 to come to the required size but while...
  2. Atooz

    Grade Beam to slab connection

    Any ideas on how to connect the concrete slab to grade beam (supported on drilled shaft). Have two options as below: 1. Can slab be casted monolithic to the grade beams? OR 2. It would be a good idea to pour them separately with sealant at the interface What is a good practice.
  3. Atooz

    Minimum Reinforcement in Auger Cast Pile

    I have seen an Auger cast pile with just two # 7 bars at the center in 16" dia pile, 50 feet deep. Which makes only close to .4% reinforcement. I think it should be minimum of 1 %. Any light this reinforcement. Has anyone seen such low reinforcement in ACIP piles. Also my research has shown...
  4. Atooz

    Pullout Strength of Tension Rebar

    Do you know how to calculate pullout strength of single tension bar usually used in pile caps. Enough distance from edges no worries about side face blowout. Some books say to use Un = 35*SQRT(Fc'). Based on ACI 318-14 Equation 25.4.2.3a, Ld would be quite large (ld=71*db) seems impractical...
  5. Atooz

    Ansys- ADPL to WB 12.1

    I have a file (*.db) created in ADPL 12.1 and trying to opne in Work Bench 12.1 Is there a way to open this. I am trying "Open" menu under the menu andgoing to the directory where the file is located but I do not see file names (*.db). Please let me know how do I do this, will appreciate...
  6. Atooz

    Select Load Direction

    I am trying to apply load in Ansys 12 in X, Y and Z Direction on Square Tube. In detail view I am choose Force under Type, Define By vector and magnitude as 100 N. The Direction I am clicking the default direction seesm to be normal to the surface. Which I am trying to chagne to lateral...
  7. Atooz

    What is an I-Tube in offshore structures

    and whaen it used as opposed to J Tube
  8. Atooz

    Slenderness Ratio for Seismic Zone

    Does any can guide me on slender ratio min/max requirement limit in the sesmic areas. With code reference will be highly appreciable. Thanks
  9. Atooz

    Cm-- Reduction Coefficient

    Has three values per AISC 9th edition, Chapter H, page 5-55. Could someone focus more light on when to use which value. Will appreciate your reply.