Dearl All,
I am trying to calculate the performance charactersitic of a LM 2500 gas turbine in our gas plants. But i have some doubts regarding to collect data, ( i ma taking data from MARK V, system control). For example the temperture T5.4 is valid to consider the combustion gases...
Dear all,
I would like to know if it possibe in realtu upgrade a LM 2500 gas turbine in a open simple bryton cycle, improve the efficiency heating the gas compressor discharge before inside the combustor chamber. In the theory is possible, but my doubt is physically in the machine ,it is...
HI,
I am Fernando and i am working as a mechanical engineer in Argentina and i am making an inspection in a heater stack.
So i am revising the calculation, i have a doubt regarding to the natural frequency calc procedure. The stack is lining, so i have to consider the refractory mass to include...
HI, I WOULD LIKE TO KNOW IF I CAN TO PERFORM A THERMOGRAPHY ANALYSIS AT 60MTS WITH A COMMON CAMERA FLIR E 25WITH LENS OF 9.2MM
BEST REGARDS AT ALL
FERNANDO
HI, I HAVE A DEMETHANIZER TOWER AND IT HAS PIR(POIISOCIANURATE) AS THERAML INSULATION, BUT WE WANT TO MAKE AN NDT INSPECTION TO VERIFY CUI. CAN I REPLACE SOME POLIISOCIANURATE WITH POLIURETHANE??
REGARDS
HI, I WOULD LIKE TO KNOW HOW I CAN TO APPLY AN IMPULSE INTERNAL PRESSURE IN A PIPING MODEL.
THE MEAN IDEA IS , FIRST IN TIME=0 CALCULATE THE DEFORMED SHAPE DUE TO THE ACELY=9.8M/S2 and internal pressure=127000kg/m2, AND IN TIME=1 SEC SIMULATE THE INCREASE PRESSURE TO 160000 IN 1 SEC (I TRY TO...
HI, I WOULD LIKE TO KNOW HOW I CAN TO APPLY AN IMPULSE INTERNAL PRESSURE IN A PIPING MODEL.
THE MEAN IDEA IS , FIRST IN TIME=0 CALCULATE THE DEFORMED SHAPE DUE TO THE ACELY=9.8M/S2 and internal pressure=127000kg/m2, AND IN TIME=1 SEC SIMULATE THE INCREASE PRESSURE TO 160000 IN 1 SEC (I TRY TO...
hi, i have to simulate a water efect (in this case is a hot-oil circuit impulsed by a pump) and i would like to know what are going on with the pipe when switch of the pump.
Can i simulate this phenomena wiht CFX?
REGARDS
hi, i have to perform a piping analysis, stress and thermal efect. I have to make it with ansys 5.4. Does any one could help me about this analysis, or show me a paper from wich i can take information.
regards
fernando vicente
HI, I WOULD LIKE TO KNOW HOW I CAN TO CALCULATE THE CO2 CORROSION RATE AT LOW TEMPERATURES (-6ºC FOR CARBON STEEL,AND -95 FOR STAINLESS STEEL304).
tHE PRODUCT IS NGL FROM THE BOTTOM OF DEMETHANIZER TOWER.
CAN I APPLY THE CLASIC MATHEMATICAL MODEL TO CALCULATE THE CORROSION RATE?
REGARDS
HI, Iam Fernando Vicente and i am mechanical engineer and i have some doubts in a work that i have to do.
We have to take some thickness measure from the DEMETHANIZER TOWER , the problem is the tower is in service and it has a COLD INSULATION whose thicknes is 180 mm from PIR...