We recently purchased B2.1-1-019-94 Standard Welding Procedure for CO2 shielded FCAW carbon steel. Our customer contact has told me that I can not use these standard weld procedures to weld to AWS D1.1 because the approval cycle would be a nightmare...he is defining the "engineering...
I have FCAW procedures that were written in 1996 as pre-qualified weld procedures using AWS D1.1. Our customer is not approving them because he feels that they do not meet the criteria of Table 4.5 as referenced in para 3.6. Specifically he has problems with the ranges we have listed on our...