  1. Deansharafi

    CTs for Reactors

    Dear all, Does anybody know if the CTs used for reactors (330KV) should have a different specification from other CTs and why? Thanks in advance
  2. Deansharafi

    High Voltage Lattice Tower Earthing

    Dear all, Do you know of any useful information or literature in relation to high voltage tower earthing, concept, design criteria, testing and commissioning etc. Thanks
  3. Deansharafi

    Clamp-on Ground resistance Testers

    Dear all, Anyone has any experience with clamp-on ground resistance testers? I am looking into replacing old ground resistance testers which operate on the basis of "Fall of Potential" method with clamp-on testers, which are quicker and more convenient. I appreciate if you could share your...
  4. Deansharafi

    High Voltage Substation Grounding (Earthing)

    Dear all, Do you know of any useful information or literature in relation to high voltage substation earthing, concept, design criteria, testing and commissioning etc. Thanks and merry Christmas and Happy New Year.
  5. Deansharafi

    Harmonics on HV motors

    Hi all, I am investigating power recordings on a site, which does not have considerable sources of producing harmonics. However I see that there are considerable harmonics on the red phase current only which seems strange to me. There are small harmonics on voltage, which is normal and small...
  6. Deansharafi

    Harmonics on HV motors

    Hi all, I am investigating power recordings on a site, which does not have considerable sources of producing harmonics. However I see that there are considerable harmonics on the red phase current only which seems strange to me. There are small harmonics on voltage, which is normal and small...
  7. Deansharafi

    Synchronous Motors

    Hi all, Do Slip ring Synchronous motors contribute to short circuit level of a power system as do induction motors? Thanks.
  8. Deansharafi

    Induction motor contribution to fault level

    Hi all, In establishing the induction motor contribution to a fault level of a system, what criteria can be considered? Are contributions of small LV (415V)motors considered significant to a fault level on an HV switchboard? These small motors normally don't have a considerable inertia and are...
  9. Deansharafi

    X/R ratio

    Hi all, What is the X/R ratio of a typical impedance used to connect generator's neutral point to earth? If you know the Impedance (Z) and don't know the X and R, it helps if this ratio is known.
  10. Deansharafi

    Switchgear Fault Level

    What is the remedy for a switchgear when its fault capacity is exceeded? Let's consider a case where generators are added to a busbar without considering the fault capacity of the board. Is there anything that can be done to rectify the situation? Thanks for your thoughts.
  11. Deansharafi

    Switchgear Fault Level

    What is the remedy for a switchgear when its fault capacity is exceeded? Let's consider a case where generators are added to a busbar without considering the fault capacity of the board. Is there anything that can be done to rectify the situation? Thanks for your thoughts.
  12. Deansharafi

    Substation Earth Testing

    Hi all, Has anyone used HV overhead lines to carry out Substation Earth Impedance testing? If you know of a written procedure for this test, please direct me to it. Thanks
  13. Deansharafi

    10 Pair flexible H.V. telephone cable

    Could anyone assist me in locating the manufacturer/supplier of flexible high voltage telephone type multicore cable. 20 core or 10 Pair with braided screen or foil and drain wire. 5kV core to core insulation 15kv core to screen insulation Bend radius to be best possible, < 10 X OD Temp rating...
  14. Deansharafi

    Resistance start for HV motors

    What are the benefits (other than controled voltage start-up)and how can a set of staged resistances can be calculated for HV motor starting. Any reading materials? Cheers!
  15. Deansharafi

    Motor Thermal damage setting

    Hi all, In setting an Overcurrent protection curve for a HV motor, how close can you design your O/C curve to the thermal damage curve? Is there any written information that I can read? I normally design my curve below the motor thermal damage curve, but I need to know what the limit is and how...
  16. Deansharafi

    Current Unbalance during start up

    Hi all, I have a client with some unbalance current problem during start up of their HV motors. They have three Siemens 6.6KV induction motors having a current unbalance @ starting of 15 - 30% for 1-1.5 seconds. They run a 6.6KV HV switchboard with 2 x 5 Mwatt steam turbines as base load and 5...
  17. Deansharafi

    Hi-potential testing on HV cables

    Hi All, I know that Hi-pot testing on HV paper insulated and screened cables is no longer recommended in the industry, but I still see it on some standards (ex. Australian Standard). What is the case for you who live in Europe or the US. Do you still do this test on HV cables? For XLPE cables...
  18. Deansharafi

    End to End testing using GPS

    Hi every one, I am doing a study into the merit of End to End testing of O/H line distance protection schemes using a GPS device to synchronise two test units at two substations, for a utility. I had done these tests three years ago and I know there are some good points in doing them, but I...
  19. Deansharafi

    Earth Fault Relay Problem

    Hi all, We have some CDG26 Earth Fault relays ( tap range 0.1 to 0.4A, DMT 3 sec) on our system and one of them has failed to trip on a feeder, as a result an upstream transformer has tripped. We investigated the relay and found out that the relay performs quite satisfactory if tested with...
  20. Deansharafi

    Metering Convention

    Hi all, What is the universal metering convention for Active and Reactive Power when it comes to power Export and Import and Feeder and Generator scenario, if any? Your input is appreciated.