  1. ClydeMule

    Pipe Fittings- Express Route

    I am having some problems with the automatic pipe fitting placement feature with the pipe routing command. I took the standard ANSI butt weld 1" elbow, created a copy, and added it to the library. I then adusted the dimensions to create 4" elbow. Using the database administrator I updated...
  2. ClydeMule

    Chilled Water Storage Tanks

    DOes anyone know of a manufacturer of chilled water storage tanks that specializes in HVAC applications. This is for a 120 ton Trane screw chiller with a short loop. Looking for around 700 gallons. Does the tank have to be rated to 125 or 150 psi, even if the system pressure will never be over...
  3. ClydeMule

    Question on Microturbines

    I am looking for some info on microturbines: 1. I am trying to make hot water or steam from the hot exhaust. I think the term is a recuperator. Turbine size is 400kw. I know Capstone makes their own for the 60 kw system, but I need to come up with an mfg independent of the Turbine manufacturer...
  4. ClydeMule

    Control System Design Philosophy

    Gentlemen, First of all, I would like to thank everybody has participated in this forum. I have been involved for the last year or so and have learned a great deal about HVAC from this forum. You can only get so much from books. I kind of work on my own and am self taught with a lot of...
  5. ClydeMule

    SEER and EER

    Dear Experts, I am looking for a good definition of SEER and EER. In general the EER is lower than the SEER because SEER is averaged over a season. EER is based on a 95 F ambient. That's how I understand it. Based on this, how can mfg's say a unit has an EER of 14? (EER not SEER). I was...
  6. ClydeMule

    Absorption Chillers

    Dear experts, Does anyone know of an mfg of small absorption chillers? I am looking for 5-30 TR range. Direct fired and waste heat fired. Thanks, Clyde
  7. ClydeMule

    Artic Master RMS-

    Has anyone seen or heard about this thing called an Artic master RMS. It used to be called a Talon RMS. The website www.articmaster.com makes some pretty impressive claims about what it can do. It is a vessel installed in the same place you would put a receiever in an air cooled system. It...
  8. ClydeMule

    Two Phase Power

    Gentlemen, I apologize for the dumb question, but what the heck is two phase power? You see it sometimes in old electrical books, in the UGLY's handbook, and people sometimes refer 220/1 sinlge as 2 phase. Is this just bad nomenclature, or is it something for real? Thanks, Clyde
  9. ClydeMule

    100% Outside air application

    Dear Experts, I would like some input on an HVAC/Chiller problem (oppurtunity). Given: 10000 ft^3 semi mobile building. (probably will never move) 12-15 volume changes/hour (2000-2500 CFM) Desired air supply 68 DB 50% RH 100% Outside Air. Outside air conditions: worst case 90 DB 90 RH. THe...
  10. ClydeMule

    Heat Transfer Coefficient

    I have a question reagrding the use of the heat transfer coeffiecnt for forced convection. The type of problem I am working on is that of a copper coil immersed in a tank of water. Chilled water is flowing through the coil. From Mark's Handbook I have found equeations to get the U from the...
  11. ClydeMule

    Heat Exchanger Sizing

    I am looking for some simple equations or rules of thumb for determining the straight length of tubing required to acheive a desired amount of heat transfer. The tubing would be formed into a coil. The coil would be immeresed in both still or agitiated water. I would like to analyze both...