Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: bnard
  • Content: Threads
  • Order by date
  1. bnard

    Ground improvement support for PE pipe on mud soil

    Hi guys hope you can help me with this. We are to relocate the existing 375 AC pipe at the toe of the road batter by laying a new 400 PE mainline about 25m from its original location. The road will be upgraded into 4 lanes and the existing ground is mud soil about 2-4m depth. Here are my...
  2. bnard

    How to support PE pipe on mud soil

    Hi guys hope you can help me with this. We are to relocate the existing 375 AC pipe at the toe of the road batter by laying a new 400 PE mainline about 25m from its original location. The road will be upgraded into 4 lanes and the existing ground is mud soil about 2-4m depth. Here are my...
  3. bnard

    Vent openings for irrigation reservoir

    We have this 7,350 cu.m underground reservoir with a height of 8.80m wherein 6.0m are underground and 3.8m is above ground. The layout is somewhat trapezoidal in shape and a two chamber system is proposed for considering the maintenance. Is there a guidelines in locating and designing the vent...
  4. bnard

    Elevations for pump and reservoir

    Hi can anyone make clarifications on how to determine the elevations of pump and reservoir in watercad when the reservoir and pump house is underground?
  5. bnard

    uPVC standards

    Hi is there anyone who has a copy of the BS 3505, DIN 8062 - ISO 161/1 for uPVC pipes? I would appreciate very much any help and suggestions thanks
  6. bnard

    uPVC to HDPE pipe connections

    Hi can anyone help me out on how a uPVC pipe will be connected to HDPE pipe. Im currently designing an irrigation system wherein the client requires us to use uPVC pipe for sizes below 225mm and HDPE for above sizes. Much will be of help if you can give me commercial sizes and specs of uPVC in...
  7. bnard

    Water network modelling

    Hi is there anyone who could advise me regarding the proper assigning of numbers of nodes in water network modelling? Is there a sequence to be followed or steps like a loop maybe in clockwise or counterclockwise? I am using epanet and watercaed software. Pls advise. . .thanks
  8. bnard

    Underpinning of structure

    Will there be any new technology where we can stabilize the foundation of existing structure aside from jet grouting procedures? especially in areas of limited space without affecting much the adjacent structures? please advise anyone thanks
  9. bnard

    Diversion of Existing River

    An existing river 3m wide with recorded water elevation at 1.25m during dry season and 2.5 during rainy season was diverted to give way for the subdivision development. Backfilling was made but compaction requirements were not observed w/c is at every 6". Residential houses built on top of...
  10. bnard

    Best location of sewer lines in a subdivision

    I am designing a 10 hectare subdivision and the space is limited. The developer wants to maximize the saleable area he can derived based from the 70 to 30% area distribution of saleable to non-saleable areas. There are no provision of easement at the back of the lot where we usually place the...
  11. bnard

    Installing manholes at drainage pipes point of intersection

    From manuals and books its a requirement to install manholes at intersection and in change of pipes sizes. I have noticed in one of the previous project in dallas, texas that they have used a wye pipes instead of manholes. Can anyone discuss its benefits and technicality? Will appreciate very...