Hi,
I'm working on Emergency / Vacuum Vents sizing on Low Pressure Tanks. I need help / guidance with calculations of relief rate for the following two cases:
1]Filling Hot Tank with Cold Liquid
2]Hot Feed to tank on startup with cooler material in tank.
How do I calculate the relief rate for...
Hi All,
Should their be a Relief Valve after a Steam Letdown Station on a Steam Header(in general) ?
We are planning to merge a 35#Steam Header into an Abandoned 15#Steam Header. The idea is to install a 35# -15# Letdown station on the 18" 35#Steam Header. The 15# Steam will be used by various...
Hello,
For a Non-ASME Relief Device(Set@ 2psig) Protecting a Non-ASME Ceritified Vessel(MAWP 2psig @ 270ºF) is the 3% and 10% RULE for INLET & OUTLET PIPING PRESSURE DROP APPLICABLE ?
Thanks,
Parimal
Hello Everybody,
I have a relief device protecting the tube side of a shell & tube heat exchanger(Process Water Heater).
The Fluid Composition is as follows:-
Tube Side - Water(90 psig normal operating, max. 150 psig) heated from 50 to 60ºC.
Shell Side - 35#Steam.
Relief Device Set @ 150 psig...