  1. vavanapoly

    Communications architecture in modern distribution systems

    CAN ANY ONE GIVE SOME FILES IN Communications architecture in modern distribution systems? The practical implementation of an 11 kV rural distributionautomation pilot scheme?
  2. vavanapoly

    Sudden Reduction of Load

    hi every body i am facing a strange problem we have a generation power station that feeding 8 OHL MV 13.8kv feeders and in one specific feeder @ peak load ( 4.2 MW ) suddenly the load goes down for 2 MW and then retain gradually to 4.2 MW withen 3-4 minutes. we checked the OHL and nothing...
  3. vavanapoly

    MV OHL

    hi every one if I have a 13.8 kv MV OHL the total length of it is 110 km and after 60 km the voltage droped from 13.8kv to 11kv is it possible to install transformers that its primary voltage is 11kv after 65km?
  4. vavanapoly

    surge arrestors testing

    hi every body i will have to do some routine tests regarding surge arrestor rated 33KV i would like to have a refrence and types of tests regarding that
  5. vavanapoly

    autoreclser

    hi every body can any one help me with the technical standard for installing autoreclosers on MV 15 KV over head line reagding distance - NO of consumers etc
  6. vavanapoly

    pole mountened transformer

    hi every one IS THERE ANY PROBLEM TO OPERATE A DISTRIBUTION POLE MOUNTENED TRANSFORMER WITH ALMOST NO LOAD? if possible can any one eplaine that for me or give me a web site that could be useful
  7. vavanapoly

    earthing wire of MV network

    hi every one is it possible to install the earth wire of a MV in top of the phases wires? and if yes can i have some info about it
  8. vavanapoly

    O.H.L

    Hi every one I would like to know whats the techniques can be used to locate any fault in MV Overhead line ?
  9. vavanapoly

    operating transformers

    hi every one > can I operate a 3 phase transformers by connecting only two phases and leaves the last phase open?
  10. vavanapoly

    cable depth

    hi every one i have a question about the HV and LT cables specifications what is the standard depth for installation a HT and LT cables? is there an equation to calculate that? the HT cable voltages are 11 Kv 13.8Kv 33Kv and 400v ? if there any site will help to understand that. and always...