  1. Ahr35181

    North American motors to TEFC-FLP-2.3.

    Can someone explain what the 2.3 indicates? Cheers
  2. Ahr35181

    Pre-ATEX Electrical Equipment - Re-use

    When ATEX first came about, I remember reading somewhere that it was ok to re-use pre-ATEX electrical equipment on new installation work (assuming the equipment is in good condition) & to re-furbish existing pre-ATEX equipment (e.g. motor overhauls). Could anybody name a standard or other...
  3. Ahr35181

    2 Speed 1 Winding 3 Phase Motors

    We have some new workshop machines purchased from abroad, the wiring diagrams for the motor starters are identical to the following:- http://www.ssusa.cc/reference/wiring_diagrams/standard_series_drawings/series_110/110_01.pdf The are rated at 2.2KW / 1.1KW, but both overload relays are set...
  4. Ahr35181

    ELV Lighting in an Machine Shop

    Would anyone no of any UK / EC standard which recommends close up machine shop lighting should be ELV rather than LV ? Thanks in advance Alan
  5. Ahr35181

    3-Phase Welding Sockets

    For many years we have used 3- phase welding sockets incorporating Emguard earth monitoring units & 30mA RCD units. We are thinking about ditching the Emguard units & just having sockets with built in RCD units. Any thoughts on this, anybody else use welding sockets incorporating earth...
  6. Ahr35181

    HV Substation Design

    I'm looking for a short course to provide me with a better understanding of HV Substation design & HV distribution. Kefax (IEE Endorsed Provider) in Mansfield do the following......Distribution System Design & Planning 5 day course. Any advice would be much appreciated. Cheers. Alan
  7. Ahr35181

    Motor Overload CTÆS

    I’ve come across two similar 60/1A ct’s, one is marked two primary turns, the other three primary turns. Does this mean two / three primary turns respectively are required to give a 60/1 ratio in each case? To me, a 60/1A ct is 60/1 with one primary passing through??? Thanks in advance. Alan
  8. Ahr35181

    Bonding Metal Cable Glands

    When terminating SWA cable glands into painted metal gland plates, traditionally we use brass earth tags with individual single core cables to an earth bar, this is not a problem in distribution panels put can quite easily over fill an earth bar in a distribution board. What do others think...
  9. Ahr35181

    Hazardous Area Fires / Explosions

    Would anyone be able to point me in the right direction in obtaining factual cases of fires / explosions in hazardous areas caused by static electricity, non suitable electrical equipment, non compliant electrical equipment installation practice, non compliant electrical working practice or lack...
  10. Ahr35181

    EMC Compliant VSD SWA Motor Cable

    According to the GAMBICA / REMA guide on best practice for the installation of Power Drive Systems (Guide 3). http://www.gambica.org.uk/ 3.4.2.3 PROTECTIVE CONDUCTOR (EARTH) CONNECTION. To operate as a protective conductor, the shield conductance must be at least 50% of that of the phase...
  11. Ahr35181

    Electro Chemical Corrosion

    I’d be interested to hear the views of others on possible electro chemical corrosion between Ex brass cable glands / copper sealing washers & Ex aluminium enclosures. Both Pirelli & Hawke recommend the use of nickel or tin plated glands, but one Ex panel manufacturer recommended using brass...
  12. Ahr35181

    Electro Chemical Corrosion

    I’d be interested to hear the views of others on possible electro chemical corrosion between Ex brass cable glands / copper sealing washers & Ex aluminium enclosures. Both Pirelli & Hawke recommend the use of nickel or tin plated glands, but one Ex panel manufacturer recommended using brass...
  13. Ahr35181

    VSD EMC Compliant Motor Cable

    According to GAMBICA, the Trade Association for Instrumentation, Control, Automation and Laboratory Technology in the UK, close wound galvanised steel wire armour offers suitable screening for VSD motor cables. Can XLPE/SWA/PVC cable to BS5467 be classed has having 'close wound galvanised...
  14. Ahr35181

    Hazardous Area Inspection Report

    I'd be interested to hear how other companies prioritise remedial work picked up during a periodic inspection of an hazardous area? At present we use the same format as shown in BS7671 GN3:- 1...Requires urgent attention 2...Requires improvement 3...Requires further investigation Thanks in...
  15. Ahr35181

    Hazardous Area Inspection Report

    I'd be interested to hear how other companies prioritise remedial work picked up during a periodic inspection of an hazardous area? At present we use the same format as shown in BS7671 GN3:- 1...Requires urgent attention 2...Requires improvement 3...Requires further investigation Thanks in...
  16. Ahr35181

    Anti Static Floor Test Sheet

    I'm looking for a typical test sheet used for recording test results for anti static flooring, any help would be much appreciated, Cheers, Alan
  17. Ahr35181

    Test Sheet For Anti Static Flooring

    I'm looking for a typical test sheet used for recording test results for anti static flooring, any help would be much appreciated, Cheers, Alan
  18. Ahr35181

    HV Protection Training

    I’m looking for a course, preferably in the NW of the UK on HV protection systems (nothing too intense though!!). Powersystems do a two day course which seems to fit the bill, could anyone advise on any other training courses? Thanks, Alan
  19. Ahr35181

    The majority (old & new) of our pro

    The majority (old & new) of our production motors (pumps, agitators etc) which are on automatic instrument control will run when the stayput e-stop is released, as the instrument contact is either closed (asking to run) or open (asking to stop). Some newer systems use a pulsed start (with...
  20. Ahr35181

    Temperature Class of Cable

    With reference to tables 54B to 54G of BS7671 it seems the final temperature of cable cpc’s are quite high & of possible concern in hazardous areas. For example, take an explosion-protected piece of equipment with T4 temperature classification (135degC) connected by XLPE SWA cable. During an...