  1. brutus1955

    seeking stamford D range info

    i am looking for information on the stamford D range alternator, the unit i am looking at is in malaysia and i am here in the states, so getting hands on look is not possible the unit is a 15kva single phase, what sets it apart is the field poles are fixed in the housing, and the rotor is...
  2. brutus1955

    measureing amperage in a 3phase circuit

    ok fella's i am trying to get my head around this, and can't seem to grasp the concept, so i come to you with my hat in hand, hopeing to get some help. i have a small 3 phase alternator, stator connected in Y configuration i am measuring 80 volts phase to phase, and 18amps at load with my...
  3. brutus1955

    generator connection wye or delta vs efficiency ?

    ok, let me preface my question 1. a three phase alternator, that can be connected in wye or delta 2. i don't care about frequency, the speed will be fixed at ~5000 rpm whether connected as wye or delta 3. the output voltage needs to be the same whether is it connected as wye or delta 4. the...
  4. brutus1955

    small diesel engine cat con ??

    ok, here is the scoop a single cylinder diesel test engine, driving a fixed load of 8kwatts (generator) at a fixed speed of 1800rpm the exhaust gas leaving the exhaust port is 640 degrees F the exhaust is going into a prototype heat exchanger i would like to insert a small catalytic...
  5. brutus1955

    generator mounting orientation ?

    we started a new forum focused on micro cogeneration and a topic came up where a guy took a 10kwatt 1800rpm genhead and mounted it vertically so he could drive it with a vertical shaft engine that he had, the question came up as to whether or not the brgs could hold up any reasonable time...
  6. brutus1955

    phase terminology question

    got into an interesting discussion the other day, and was not able to express myself clearly the question... if you have a single phase alternator, 60hz 2 pole 3600rpm and there are two windings, winding A=120vac, winding B=120vac how do you refer properly to each winding? can i use "phase a"...
  7. brutus1955

    converting alternator 3/0 to single phase, capacity?

    if i have a 12kva 3 phase alternator that is connected star/wye and i want to run it as single phase, what is its new capacity? for some reason i have something like 58% of 12kva, but can't remember where i get that except it is the reciprocal of the 1.73 delta to star/wye voltage multiplier...
  8. brutus1955

    looking for an engineering text alternator design

    i know well how they work, and all that what i am looking for is a more current text on alternator design, something very indepth and that gets into all the math, materials, and other design considerations. an engineering text so to speak i would expect it to sell in the 200+ dollar range, i...
  9. brutus1955

    alternator power factor driving a rectifier

    if we have an alternator, it produces AC and assume it is 3 phase for the sake of discussion attached to the alterntor is a bridge rectifier to convert the AC to DC the power factor of a circuit driving a rectifier is reportedly something less or often much less than unity now granted an...
  10. brutus1955

    DC shunt/meter amperage problem

    figured i would try you guys on this one i am working on a prototype alterntor, 500hz 57.6vdc at 75-100amps i have a yokogawa analog dc amp meter (50mv) with its 500amp shunt, so i can read up to 500amps with decent resolution. it has worked well with other alternators, but not this one it...
  11. brutus1955

    ? about parallel operation of inverters

    what i want to try to do, is to take two ups inverters, tap the first at the logic drive to the FET's driver, and jumper this logic over to a second inverter which has had its logic disconnected. the goal is to be able to then parallel connect the outputs of both inverters for more power is...
  12. brutus1955

    avalanche diodes in automotive alternators

    i have no idea where to get an answer to this one, so i come here hoping to get an explanation. the alternator i am working with has what is called avalanche diodes in the bridge rectifier, they are supposed to go into avalanche at ~29volts or so. from what i can tell there are some...
  13. brutus1955

    need info on programming a GE CL200 kwattmeter

    i am trying to setup a test cell for a prototype multimode trigenerator, and was looking for a reasonalby priced means of reading AC kwatt info. i picked up a new GE CL200 meter head off of ebay, it is a new one, but appears to be not programmed? it has a digital screen, and the little lever...
  14. brutus1955

    altenator design question

    i figured i would try here, thinking perhaps there are those in the design of alternators on the forum :) i have a project that i am working on, i will first lay out the parameters of what it is i have to work with, and what i am trying to do,, followed by a question. i am working with a...
  15. brutus1955

    stationary engine mounting info needed

    i have been researching the answer to how i can decide on the dimensions of a concrete base for a single cylinder diesel engine. is there anyone on here that can lead me in the right direction or help me to find source information. thanks bob g