  1. Mondolfi

    API 2000 - API 650 Fire Venting

    For safety devices the overpressures indicated as 20% and 10% above maximum allowable working pressure apply to API 620 tanks only. As indicated in 4.5.1.1.4, these conditions do not apply to API 650 tanks where the internal design pressure should not be exceeded under any normal operating...
  2. Mondolfi

    RhoV2

    Hi, Can anyone explain me what is the use or the importance of the term RhoV2 in the desing of a flare header collector? Thanks in advance,
  3. Mondolfi

    HYSYS 3.0.1 BUG

    Hi, After some painful headaches simulating a Amine Regenerator System with HYSYS 3.0.1 (Amine Package selected) and with the help of another forum partner (PHP78), we have come up with the conclution that this version has a bug in amine package. For more information on this matter, please...
  4. Mondolfi

    HYSYS 3.0.1 BUG

    Hi, After some painful headaches simulating a Amine Regenerator System with HYSYS 3.0.1 (Amine Package selected) and with the help of another forum partner (PHP78), we have come up with the conclution that this version has a bug in amine package. For more information onthis matter, please...
  5. Mondolfi

    Flame Propagation Velocity

    Hi, Where can I found a method for calculating the flame propagation velocity for gasoil and gasoline? Thanks in advance
  6. Mondolfi

    HYSYS MDEA SIMULATION

    Hi, I`m working on a MDEA Reg. Unit. and I'm using HYSYS 3.0.1 (amine package)but I'm having a little problem with this. I have a surge drum before regenerator tower;According to H&MB, the drum is adiabatic and DP=0. Vapor flow in this separator should be near zero @T,P, but for some reason...
  7. Mondolfi

    FLARENET

    Hi, does anybody have an electronic Reference Manual for Flarenet 3.0? Thanks,
  8. Mondolfi

    Equivalent Length

    Hi, I´m looking for Equivalent Length factor (L/D) for a standard pipe enlargement (lets say 30º angle). Although I’ve found this values for elbows and tee’s at CRANE’s, enlargements (and other fittings) usually depends of a K factor, involving density, velocity, etc. Any suggestion for a...