Hi,
I need to size a tank that will supply a pump that will pump water to a number of hose reels around our site. What information do i need to enable me to calculate the tank size?
Thanks
Clarke
i need to detect when dust is present in an exhaust stack and was wondering if anyone knows of any probes or sensors that could be used. I have heard of using triboelectric sensors but these are exspensive and seem to be abit ott for what i want. I have tried using a differnetial pressure switch...
Hi,
How do open an excel spreadsheet/workbook from wincc and then enter data into specific cells, also how can i change to a differrent sheet in the same workbook.
Iam using version 5 of wincc.
Thanks in advance for any responses
Clarke.
We Have a conveyor installed outdoors with a 3 phase supply to motor and stop/start push buton station, my question is are there any special requirements for 3 phase outdoor supplies i.e rcd protection and earthing, like single phase domestic supplies??
Hi
I have a number of product scales that I need to take the flow rate from. I am using an s7-400 plc, there are several different types of scale a number of them can easily be connected to profibus, but other older versions only have a 240v pulse output each time they tip which at the moment...
we have a machine for grinding product, when the machine grinds the finer product passes through a screen with the larger product passsing out of the end of the machine. If the screen gets a hole the larger product contaminates the finer. My question is does anyone know of a sensor that could...
I want to connect my laptop to our s7 400 plc through our ethernet network, I know it can be done because our contractor uses this method. The problem im having is setting up the siemens netpro (I think thats what its calle) software for my ethernet connection. Can anyone help
We have a large machine with two discs rotating at high speed, to shut down the machine if it becomes unbalanced a vibration switch is to be fitted. I have to send a signal to an s7 plc via an et200 rio panel to signal that the vibration switch has been triggered. Is it o.k to let the plc...
We are looking to upgrade are existing modicon quantum plc to a seimens s7-400 plc is there anyway to transfer the program directly to step7 or will I have to re-write the whole program. We currently program the modicon plc using modsoft 2.6.
can anyone tell me what types of maintenance should be carried out on an electrical maintenance schedule. I realise that a lot depends on the plant you're maintaining but im just looking for a general guideline.
hope you can help
We have four atto power misers installed in two mcc's there are no contactors fitted only the thyristor control for the motor. The problem is when one powermiser starts if the other power miser in the same panel is running it will shut down the same will happen if one happens to go into...
Hi
We have four energy saving devices (Atto power misers) fitted to 75kw motors, we have two mcc's fitted with two power misers each, If one of the powermisers has the mccb switched off then back on whilst the other powermiser in the same panel is till running that powermiser shuts down, a...
Hi,
My company have recently installed some fischer emerson valves that use hart protocol for control. We have recenlty had problems with one of these valves and wanted to test/calibrate the valve in the workshop but couldnt get it to work with a 4-20mA signal. My question is are there any...