Hi,
I will ask the Chemical Engineers the same question I asked the Materials Engineers and hopefully someone might have some knowledge.
I have a Grade 17 Titanium Autoclave that needs to be temporarily decommissioned for 3 months. It is currently in service for a high pressure sulphuric acid...
Hi,
I am looking at ways of temporarily decommissioning (for 3 months) a Titanium Grade 17 autoclave. The autoclave is in service for Pressure Acid leaching of Nickel laterite ore. The conditions are 45 g/L sulphuric acid at 250 degrees C with 70 g/L chlorides.
Does the titanium need to be...
Hi,
does anybody know where I can get an idea of corrosion rates of Carbon Steel ? Specifically in a high temp, chloride sulphuric acid environment?
A special lining on a tank has failed due to large particle erosion. The steel shell is suspected to be exposed and I would like to be able to get...
Hi,
I am trying to determine the expected vent gas flowrates for a Nickel Laterite pressure leaching autoclave. The current pressure control valve is inoperable, as it is too large and vents too much gas when open, making pressure control difficult.
I have determined that N2 is negligible in...