Hi Everybody.
I wanted to know if it is advisable to spray water directly on the fins of a large V shaped air cooled condenser or shall i use a celdek evaporative pad before the condenser coils and spray water on the celdek pads.
What could be the advantages and disadvantages of using either...
Hi Friends,
I have come accross a few calorimeter test results for condensers and evaporatos, but the readings do not make sense to me, as i am not exactly aware at what points the readings are made.
can you provide me with some details regarding the schematic diagram of a calorimeter test...
dear all,
i have been using and designing the shell & tube heat exchangers using the book of d q kern. process heat transfer
can anyone suggest a book for designing tube & fin type of heat exchangers used in the air conditioning and refrigeration industry.
thanks in advance
dear all,
i have been using and designing the shell & tube heat exchangers using the book of d q kern. process heat transfer
can anyone suggest a book for designing tube & fin type of heat exchangers used in the air conditioning and refrigeration industry.
thanks in advance
Hi all.
I ve been designing some mini air cooled condeners using shaded pole motors.(5W through 16W)The motors are with ball bearing.
But in USA people usually use the unit bearing motors.
What is the differences between these two type of motos.
I would like to buy the unit bearing motors, any...
what are the general procedures for getting a UL listing for condensers and evaporators.
we also wanted to test condensing unit performances using two/three condensers of different make.
Is ther any perticular agency/test lab in india who can do these type of teting.
thanks and appreciate your...
Hi all.
We are using tube and fin type fin fan cooler to cool the lubrication oil of our 10 MW gas turbine.
During high abient temp. the oil temp. rises very high.
Please inform if there are flow retarders or heat transfer promotors available which can be inserted into the tubes, to increase the...
Hi all,
We intend to buy a helium testing machine to test our coils.
can anyone provide with the names of suitable manufactures of these machines.
I understand that there will be escape of helium gas due to the leakages, is it dangerous for the operators
regards
hi !
could you guys help me source connectors / terminal blocks for two core wire 2.5mm2 (10 amps) for single phase motors having two clip type lug connections and from the power source the wire will be having two pin type lug connection.
The connector will be mounted on a sheet metal frame with...
we are manufacturers of automibile air conditioning kits.
we also use the txv's. need help in sourcing a suitable manufacturer for the pipe assembly for the txv valves.
thanks
vinod
hi all,
i am trying to design a condensing unit.
how do i calculate the cooling capacity of the compressor when the compressor hp is known.
i will be using the hermatic compressors of 1/4 to 3/4 hp.