Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: lotus7312
  • Content: Threads
  • Order by date
  1. lotus7312

    new facility master validation plan

    Hi, We are constructing a new pharmarceutical facility now. I was ask to come up a master validation plan. Can someone give me some guildance or example plan? What items should I check for buildings, utilities and HVAC system? Many thanks
  2. lotus7312

    pH adjustment for RO purified water system

    We are designing a purified water system with one stage RO. One article about RO system said the pH of the water inlet to RO has to be adjusted to above 8.3. The reason is there will be only HCO3- and CO32- ions in the water, and not CO2 gas since RO can not reject CO2 gas. Does anyone use RO...
  3. lotus7312

    minimum water outlet temperature that a cooling tower can reach

    Hi, all, Do you have any idea that the minimum temperature of the water outlet that a cooling tower(natural draft/mechanical draft) can reach? Thanks
  4. lotus7312

    Hot oil system design

    Hi, all, We plan to build a hot oil boiler to heat all the reactors in our plant. Due to the different temperature requirement of individual reactor, someone in our company brough up the following design: 1. Feed a medium(say kind of oil) in the reactor jacket 2. Install a sort of...
  5. lotus7312

    Vacuum pump installed in a high position can give better vacuum

    Hi, all, My boss said that somebody told him that if a water ring vacuum pump was installed in a high position(say, on the roof of the plant), then you can get better vacuum. Did anyone hear about this? Is there any theory or logic behind this? Thanks
  6. lotus7312

    heating/cooling control

    Dear all, I have one project to get a better control for a vessel during heating/cooling. There are steam and water line for this vessel. Currently,steam is on for a few minites to reach to certain temperature. Then open water vavel and crack steam valve to maintain the target temperature. My...
  7. lotus7312

    inductive load

    Hi, all, Can anyone explain the sentence below? Inductive load: 50VA @120VAC OR 240VAC What if the voltage is 220VAC? THANKS
  8. lotus7312

    solenoid valve and controller

    Dear all, I have a solenoid valve with 220V/50Hz. Can I use a controller with on-off control relay to operate this solenoid valve? Thank you
  9. lotus7312

    class F coil with 18" lead

    Dear all, Can anyone tell me what is the meaning of (class F coil with 18" lead)? Is there any other class of coil? What is their major difference? Thanks a lot
  10. lotus7312

    Can a vacuum system be used in condensate receiver?

    Hi, all, I am wondering whether a vacuum pump can be used to assist condensate flow back to a condensate receiver. Normally, there is a vent in the receiver to vent the flashed steam generated by high pressure condensate. How can I handle the flashed steam problem if a vacuum is used? What kind...
  11. lotus7312

    M2 controller

    Hi, all, Does anyone have some ideas about the M2 controller? How does it work? What's the adventage? What is the difference between this controller and the other controller? Thanks
  12. lotus7312

    Condensate return system

    If there are two reactors heated up by steam. The steam header pressure is same, say 6 bar. But the two reactors need different steam pressure due to the different process(say reactor 1 needs 5bar which reactor 2 needs 1bar). Therefore, the inlet steam pressure is regulated by cracking the...
  13. lotus7312

    vacuum knock out system

    We have water ring vacuum pump. When we pull vacuum from reactor, organic fumes will come out of the reactor and enter into the vacuum pump water line, which cause contamination issues in my waste water system. We tried to keep the water into a circulation tank without any cooling, but the water...