  1. sky72

    Back Enegize of Transformer

    Can we enegize a 240MVA 275/132kV step up transformer under no load condition by using the 132kV source due to 275kV incoming line is not ready. The 240MVA transformer will put under "soak" condition. BTW, can we use a step up transformer as a step down transformer? Thanks.
  2. sky72

    Short Circuit Rating

    May i know why equipment short circuit rating for 500kV is 50kA/1sec not 50kA/3sec if compare to 275kV which is 31.5kA/3sec. Thanks.
  3. sky72

    Transformer Oil / Power Factor

    Hi, May i know what are the advantages using naphthenics base transformer oil compare to paraffinic base? And, if the specification of transformer bushing power factor is < 0.7% at 20 degree C, what is the correction factor if i measure the bushing power factor at 34 degree C? Thanks.
  4. sky72

    Lightning Protection / Earthing Screen

    I need some information about earthing screen which protect the outdoor equipment (high voltage switchgear - conventional type/air insulated) from direct lightning strikes. The earthing screen required to cover the whole plant using graphical methods (Rolling Sphere Method). Appreciate...
  5. sky72

    Polybuthene Oil

    Transformer cable box which have two compartment, one is filled with transformer oil (disconnecting chamber) and the other one fill polybuthene oil (power cable box). Unfortunely, the tranformer oil from disconnecting chamber leaks to power cable box and mixed together with polybuthene oil. We...
  6. sky72

    MV GIS

    I received a statement from supplier as below: "GIS MV switchgear shall be used instead of AIS MV switchgear for substation located altitude >1500m above sea level. The voltage correction factor is about 0.7..at this altitude" Could you please advise this statement is based on what standard...
  7. sky72

    Oil Dielectric test

    Could somebody explain why the transformer oil (275/132/33kV auto-transformer) can pass the dielectric test (2.5mm gap) with breakdown voltage above 70kV but fail the moisture content test i.e. sample from main conservator: 16.55ppm & On load tap changer compartment: 27.97ppm)? Thanks.
  8. sky72

    Automatic Voltage Controller

    Hi, can someone advise me on automatic voltage controller(AVC). I need to know where can i find this AVC. The specification for the AVC as below: - The shunt capacitor shall be equipped with automatic closing and opening control option. A switch shall be provided at the control panel to...
  9. sky72

    132kV connectors

    Can someone guide me how to choose the right connectors for 132kV outdoor substation. For example,from busbar isolator to circuit breaker, what type of connectors and how many spacer needed (for twin conductors)for this arrangement? In short, i need the details design for the outdoor...
  10. sky72

    Clamps and Connectors

    Can anyone guide me on the HV (132kV & 275kV) outdoor substation design especially on the clamps and connectors details the following arrangement: - surge arrester - capacitor voltage transfomer - line isolator - current transformer - circuit breaker - busbar isolator FYI, conductor used to...
  11. sky72

    Tangent Delta Test

    Hi,can someone tell me more about tangent delta test especially for auto-transformer i.e. purpose of tangent delta test and test procedures.
  12. sky72

    On line oil filter

    Why the SF6 intefacing 240MVA auto-transfomrer need this on line oil filter while the AIR type not required? Thks.
  13. sky72

    Isolation current transformer

    Why we need to have an isolation current transformer for metering if we using the 600/300/5A, class 5P20, 15VA ring type current transformer for overcurrent and earthfault protection?
  14. sky72

    on line filter

    can someone tell why we need this on line filter for auto-transformer?
  15. sky72

    isolating current transformer

    May i know the principal of isolating current transformer? Thanks.