  1. electromike

    Sizing thermal OLs on motor starters with CTs vs. starters with no CTs

    I have encountered a situation with GE motor starters where the OL selection chart for a size 5 starter with CTs and a 168 Fla at 150 hp calls for almost a double size heater element than what would be expected with a 5 amp secondary current on the CT. The heaters recommended by the chart would...
  2. electromike

    Inverter grade scr vs. phase control scr

    I would like to know what electrical parameters make the difference between a inverter grade thyrister and a phase control thyrister? I am tring to cross refrence an old obsolete inverter grade thyrister in an attemp to make a quick repair to a UPS system at my facility that has a shorted scr in...
  3. electromike

    Codes for steel tubing in hydrogen service?

    I need to know which codes,API or ANSI ect., cover the installation of compresion and threaded steel tubing used in high pressure hydrogen gas service. This information is needed after an incident where a maintenance technican changed several 3/8" tubing valves in a valve/regulator tree fed by...
  4. electromike

    % Difference of DC resistance in AC motor stators

    Does anyone know what an acceptable "Standard" percent difference of DC resistance one should find in LV 3 phase motor stators?
  5. electromike

    Switching neutral in 120v control

    Does anyone have experience with switching the neutral instead of the "Hot" conductor in control circuits except in motor starter buckets. I have encountered this practice on a DCS system in a chemical manufacturing facility.I am told this is a safer practice in that all conductors in the field...
  6. electromike

    Exploding MV motor weatherheads?

    I have seen ground faults inside junction boxes at MV motors do a good deal of damage to the enclosures.(There have even been reports of fatal injuries to people near the motors when such happens.) Lots of "arc" damage will be present but not with my newest MV fun! In the most recent incident...
  7. electromike

    Dual Delta-Wye Secondary Transformer Question

    Why would a medium voltage (2300v)AC variable speed drive have a dual secondary (6 leads out) supply transformer feeding the the front side (12 pulse rectifier)of the drive? Is this transformer needed of does it serve some added benifit?
  8. electromike

    VFD driving two different HP and slip motors

    What sort of problems should I expect if I have a 10 HP 1695 rpm motor driving one side of a 10 ton bridge crane and a 15 HP 1720 rpm motor driving the othe side of the same bridge? Both of these motors are powered by the same VFD that uses an open loop V/F control method.
  9. electromike

    Two induction motors paralleled to one VFD output?

    I was wondering if there were any special considerations that should be known befor attempting to parallel 2 identical 3-phase induction motors on one vfd output.The motors will be driving a sled via rails. There will be a motor and gearbox at each side of the cart to drive the cart on the...