One daft question regarding the difference between fire pump UL/FM approved and general pump in the same capacities apart from its price. Technical aspects only !
Test method? material components specified ? or even some prohibits according to the related code, NFPA ?
please shed me some...
If we have the model of fire pump and its controller, how can we make sure that these models are UL listed/ FM approved?
Is there any source on the internet to prove it?
Thanks in advance for your kind advice.
Dear Sir
If we have the model of fire pump and its controller, how can we make sure that these models are UL listed/ FM approved?
Is there any source on the internet to prove it?
Thanks in advance for your kind advice.
Dear All
I'm curious about NFPA20 regarding installation of pumps for fire. I have two questions as follows
1. In my (basic)point of view and apart from the jockey pump, I understand that A/C motor-driven fire and/or Diesel engine-driven fire pump will be set to automatically start at...
Dear Sir
I need your kind help to enlighten me from my (chronic) problems that I usually face with. I'm mechanical engineer so I'm not keen in material aspects in details really. Here are my questions
1. How can I compare material grade between different standards JIS, ASTM, DIN etc? Many...
Dear Sir
Does anyone have any idea about the normal (suitable) material for the HRSG stack silencer or so called "buffer" installed INTERNALLY inside the stack?
Please share me your experience regarding this matter.
Thanks for your kind help
Best Regards
Dear All
I have reached to the dead end of my decision with the main contractor for Power plant construction. I have a major problem of tube removal due to limited space. Our contractor said that their titanium tubes were not required to be removed for maintenance so they did not provide a...
Dear All
After reviewed several threads talking about pressure loss calculation in pipeline (all type of fluids; compressible, incompressible etc.), I would like you to share your partical and competent experiences in this matter.
My first question is whether or not there are any recommended...
Dear All
I'd like to know that if i can use motor actuator for the control valves (regularing purpose, not on-off purpose). Normally we use the pneumatic actuator for this kind of control; such as desuperheater, feed water system and so on. Even though I know the motor actuator of which...
Dear All
I'm a mechnical engineer in the power plant. I'd like to know that if i can use motor actuator for the control valves (regularing purpose, not on-off purpose).Normally we use the pneumatic actuator for this kind of control; such as desuperheater, feed water system and so on. Even though...
Dear ,all
Could anyone tell me about the criteria for applying manhole for the underground pipe? on the questions below
1. Is there any recommendation, practice or standard specified that what the pipe size should be provided manhole(s)along the pipeline for maintenance purposes? 500 mm up ?
2...
Hi all ,
I would like to know the value of the (inside)corrosion allowance used for the minimum wall thickness calculation as ASME section I is. Someone told me there's no need to concern about it because the quality of water in boiler is very good but I don't think so. Is that true ? Can...