  1. ozmongoose

    T diamond in SAMA diagram ?

    Hi all, Need your explanation about the T (Transfer) in the diamond in SAMA diagram. What is the physical meaning ? Why is it always placed in between PID controller output and actuator ? Thanks a lot Mongoose
  2. ozmongoose

    How to eliminate harmonics on DC link in 4 quadrad inverter ? Pls HELP

    Hi all friends ! I got a problem with my experiment. A DFIM is controlled from rotor side by a bach to back VSC. DC link voltage is at 700V. Capaccitor on DC link: 1470uF, Reactor at AC input of Power Unit : 4.8 mH. The whole control system is programmed by myself with dSpace. Problems: If...
  3. ozmongoose

    How to eliminate harmonics on DC link in 4 quadrad inverter ?

    Hi all friends ! I got a problem with my experiment. A DFIM is controlled from rotor side by a bach to back VSC. DC link voltage is at 700V. Capaccitor on DC link: 1470uF, Reactor at AC input of Power Unit : 4.8 mH. The whole control system is programmed by myself with dSpace. Problems: If...
  4. ozmongoose

    Controlled Rectifier Problems

    Hi I got a problem with my experiment. The task is how to regulate a stable DC link voltage (620-640V) by controlling a Power Unit PU (Baumueller Bus623) with PWM on IGBTs. Voltage supply 400 VAC, Capaccitor on DC link: 970 microF, inductance at AC input of Power Unit : 3.625 mH (3 phase). Imax...
  5. ozmongoose

    RC Filter or LC ???????

    Hello WE are designing a converter to control a induction machine. The converter uses the IGBTs (8KHz) to create the AC current. We know that a filter at the output of converter is necessary. But I can know if I should take a RC filter or a LC filter. Can anyone tell me how and when we chose one...
  6. ozmongoose

    Help to measure doubly fed induction machine PARAMETERS

    Can any one show me a solution to measure the AC 3~ Doubly Fed Induction Motor Parameter like Rs,Rr,Ls,Lr... Offline&Online? I supposed that we have the Information of the Motor from the LABEL Ulst=180V ; 7,5KW; delta /star ; 50Hz; cos_phi; 1/min; Rot_A 16,3/9,4 (A)...
  7. ozmongoose

    LEM Voltage Transducers (difficult to use ????)

    I have bought the LEM Voltage Transducers LV 25 -P for my experiment. As recommended in the datasheet, I used the RM as 100 Ohm, RM = 26KOhm to measure the voltage of 250V AC. The supply DC voltage is +/- 15VDC. But the measured voltage at terminal M is always at 15V when V HT is > 0 , and...
  8. ozmongoose

    Motor protection ???

    Hi all I got a 3 phase Doubly fed induction motor 7,5KW,230V/400V,50 Hz, rated rotor current 27A. I used 1 converter to control motor, connected to the Rotor side, start connection. In between motor and converter, I would like to use a Crowbar, and a Switch (0-1-2). The crowbar is for motor...
  9. ozmongoose

    Motor protection

    Hi all I got a 3 phase Doubly fed induction motor 7,5KW,230V/400V,50 Hz, rated rotor current 27A. I used 1 converter to control motor, connected to the Rotor side, start connection. In between motor and converter, I would like to use a Crowbar, and a Switch (0-1-2). The crowbar is for motor...
  10. ozmongoose

    AC Motor Parameter Identification

    Hi Can any one show me a solution to identify the AC 3~ Induction Motor Parameter like Rs,Rr,Ls,Lr... Offline&Online? I supposed that we have the Information of the Motor from the LABEL 380V/660V ; 7,5KW; delta /star ; 50Hz; cos_phi; 1/min; Rot_A 16,3/9,4 (A) 0,82...