Hello All,
This may be a very stupid question. But Why is the reason that we set pressure relief valve higher value than the Maximum allowable pressure value?
For example: I have a system which has a maximum pressure 75 PSI (limited by pump) but the pressure relief valve is set to 90 PSI...
Hello All,
A very quick question to all. Could somebody explain me the the effect of the GAP on the performance of the blower in the image attached? How closly that gap needs to be controlled?
Blue is Air OUT, Green is AIR IN from the blower.