Good evening Dear colleagues,
This is a cyclic test of a metallic brace surrounded by a box of concrete. The brace resists axial loads (tension and compression), and its concrete role is to prevent this brace from buckling in the case of compression. There is a gap of 1 mm between the brace and...
Hello,
I have some problems with my Abaqus model, the job ran successfully and complete the time but the result is not as desired, the model shows a deformable shape and the hysteresis curve failed to get symmetrical loops.
the model is a metallic damper under cyclic loading.
step= static...