Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Snatch
  • Content: Threads
  • Order by date
  1. Snatch

    Steel frame masonary wall connection

    I am working on the construction of a small warehouse builing 60' X 40'. The building is a steel framed building with masonry blockwork as the walls. I am looking for the best means to connect the steel frame and masonry blockwork, in particular the steel column masonry block wall connection or...
  2. Snatch

    Information on Steel Suppliers

    We are putting together a proposal for the feasibility study and design of a small steel stadium for a soccer field. Can someone recommend a steel manufacture/ fabricator that we can assist in quoting on the design and supply of the steel elements of such stadium, preferably in the USA...
  3. Snatch

    Inflation of prices after contract award

    I am working on a housing development project, as part of the contractor's team. After signing the contract the cost of cement has increased by approximately 25% . The contract states that there will be "no revision in prices". The option we are thinking about is to claim under force majuere...
  4. Snatch

    Voids in rock stock pile

    I am working on an earthworks project and have to come to an agreement with the contractor for the volume of rock (solid boulders) excavated. The contractor has surveyed the rock stock piles using a total station and computed the volume using modeling software. We are reasonable comfortable with...
  5. Snatch

    Contract documents & specifications.

    All, I am working as a civil engineer in a newly developed consultancy company. I am seeking guidance for purchasing contract documents (form of tenders/ agreements etc.) and specifications for civil and building projects with the intention of the firm representing the clients on these...
  6. Snatch

    Settlement problems on fill playing field

    I have been asked to advise on settlement problems at a recreation field that was constructed about 3 years ago with a cut/fill operation, the maximum depth of fill being approx 30’. I am uncertain to the compaction achieved whilst carrying out the initial construction of the field, however...
  7. Snatch

    Lumps of clay in floor slab

    We poured a 8" thk floor slab about a month ago, on the day of the pour the surrounding ground was wet. We poured it using wheel barrows and apparently some clay particles have been left behind in the slab (from the wheels and off the shoes of the labourers). We noticed pockets of cracking and...
  8. Snatch

    Cracks in concrete roof slab

    I was asked by owner of a newly constructed building to inspect cracks in the top of a concrete roof. The building was constructed in April this year. The cracks were noticed because after heavy rainfall water would leak through the slab and into the building. The crack widths are about 3mm...
  9. Snatch

    One point proctor method

    I am working on an earthwork project, which consist of a cut and fill operation. The specification for filling requires a compaction 95% Maximum Dry Density with +/- 2% Optimum moisture content. The geo-technical engineer for the contractor is suggesting using one point proctor method to...
  10. Snatch

    Concrete cube testing problems

    I am working on a project in which concrete cube samples were taken. Tests were carried out at 3,7,28 days, the specified strength was 4000psi. Unfortunately the samples were not placed in a water for curing. After crushing samples at 28 days, the strength were much lower that 4000psi. Can the...
  11. Snatch

    Specifications for Contract Document

    Hi All, I am trying to put together a contract document for some "minor civil works construction". Does anyone know where i can find some general specifications online?. Typically for excavation, concrete works, formworks etc... Thanks in advance SN
  12. Snatch

    Concrete slab on metal decking

    Is only anticracking reinforcement specified for these slabs? My problem is a steel building was purchased and the concrete slab and reinforcement were not specified for the metal pan decking. I have no literature on how to design such (one way) slabs . The span is 8 ft so I estimate that...
  13. Snatch

    Concrete slab on metal decking

    Is only anticracking reinforcement specified for these slabs? My problem is a steel building was purchased and the concrete slab and reinforcement was not specified for the metal pan decking. I have no guidance on how to design the (one way) slab. The span is 8 ft so I estimate that 6" max...
  14. Snatch

    Extensions to small buildings

    When extending a building, say a two storey dwelling, should the new members (beams, columns footings)be 1. joined to the existing members by dowelling or exposing rebar splicing new rebar and concreting or 2. not be connected at all, allowed to act as separate structure all together?
  15. Snatch

    Mechnical workshop foundation design

    Hi, I would like some advice, I have given the task to design the foundation of a new mechanical workshop in my department. The building will be a steel framed structure. I am responsible for designing the pad footings for the columns and the floor slab. I have a few questions: 1) Do we need...
  16. Snatch

    Moments check

    I am designing a one storey reinforced concrete frame building (9.15m by 30.39m). Height 4.42 m. Walls on exterior only Nine frames I set up are at 3.811m intervals, consisting of 2 columns each and 1 beam spanning 9.15m. The loading for interior frames are as follows: 1. seismic 398 kN at roof...
  17. Snatch

    Earth road

    Can anyone inform me as to the maximum longitudinal slope recommended for an earthroad. One of my concerns is erosion by water. DW
  18. Snatch

    Retaining wall on 24% slope

    I would like some advice on a project that I am working on. The scope of the project is to design a reinforced concrete retaining wall along a sloping site (slope 24%). I have tried to use the stepped footing approach but it requires excessive excavation. Can I use a footing inclined parallel to...
  19. Snatch

    Selection of a structural engineering software

    I am a freelance strutural engineer, i am presently doing alot of analysis for wind and earthquake loadings of reinforced concrete building structures( not usually greater the 4 storeys), retaining walls, and also timber roofs of houses to B.S Codes. This analysis is very repetitive. Can anyone...
  20. Snatch

    Retaining Wall

    Hi I have designed a retaining wall to retain soil pressure and over burden pressure from a foundation of a house about 2 meters away. The height of the wall is 4.57m high. My design produced a 330 mm thk wall with T16@125 c/c main reinforcement, vertically ( designed as a cantilever). My...

Part and Inventory Search