  1. neps3

    Current Transformers

    Hi Request information on failure modes of current transformers, Post type, bobbin, resin insulated upto 17.5kV from your experience please. Thanks neps3
  2. neps3

    Neutral Displacement

    Hi The VT used on a 11kV generator SWBD bus has 11/SQRT3 / 110/SQRT3 // 110/SQRT3. The third winding is an open delta used for neutral displacement relay. Usually generators have 11/SQRT3 / 110/SQRT3 // 110/3. However, a gas turbine set have the 110/sqrt3 for the open delta. What setting does...
  3. neps3

    Bus Bar Inductance

    Hi Could you please give me the formula for the inductance of a single bus bar of L metres. Bus bar of flat shape. a=width b=height Thank you
  4. neps3

    LV Cables

    Hi All Could you please give me the minimum insulation resistance of 415V cables (power) and the standard which applies. Thanks
  5. neps3

    Firewall

    Hi All Could you please advise on a good free firewall program from a web site. Ta
  6. neps3

    Hi All I am looking at transform

    Hi All I am looking at transformer protection for upto 70MVA 11/132kV. Could you help me out with good protection. I know ABB and GEC. Any other in the market place and web address please. I am looking at digital unit all in one complete with software. Thanks in advance
  7. neps3

    Hi All I need help in the calcul

    Hi All I need help in the calculation of dielectric loss (W/cm3) when subjected to a 50Hz AC supply. ie 4kV/mm. Assume a tan delta value. Thanks in advance
  8. neps3

    6.6kV Terminal Box explosion

    Hi This is an intersting piece of puzzle and I would like to welcome those interested to analyse and contribute. Transformer size -20MVA, 15.75/6.6kV 15.75kV connection is via the PIB. Terminal Box 6.6kV- 3 cables per phase. 400sqmm Aluminium. 6.6kV bushing is vertical and the palm is Copper...
  9. neps3

    415V motor failure

    Hi We had a stacker boom conveyor motor rated 415V 150HP, 1485rpm failed. On inspection the failure was observed to be in the overhang area at the NDE. The failure looks like turn to turn and then to earth. Two phases are down to earth. The motor is controlled by soft starter for starting. The...
  10. neps3

    Homopolar generation

    Hi Can you help me with the homopolar generation phenomenon, turbine rub, superheated steam electrical characteristics and the bearing current pitting.
  11. neps3

    Homopolar Generation & HP Turbine

    I like to know the phenomenon of electromagnetism in the HP turbine due to superheated steam at around 550C (Homopolar generation), turbine rub, bearing current pittings. Could you help please.
  12. neps3

    Electromagnetic Disc braking

    Could an expert engineer please help me with the formulae for disc braking with electromagnetic coils. This is the eddy current braking. Thank you.
  13. neps3

    BHP reduction due to increase in poles

    When a four pole 0.85 power factor 355kW motor is rewound to a six pole motor, the power output kW reduces approximately by two thirds with a lower power factor while maintaining the same Torque. Any comments please.