We have having WPS with impact test at -29 Deg.c for FCAW process. as per ASME SEC-IX.
Now new filler wire brought having same SFA NO but different brand name from same manufacturer. Mechanical properties were same. Impact test carried out at -40 Deg.c
We need to qualify new PQR or Proceed with...
We have API 650 stainless steel storage tanks of 3m and 4m dia bottom plate having butt weld configuration without back strip.
The weld joints on soil side required Pickling and passivation?.
Soil side no painting.
Regards,
Shanmuga
In our API 650 tank project we have curb angle to shell welding - Butt welding with full penetration.
My query is now the curb angle is considered as permanent attachment and NDT requirement have to be followed accordingly or permanent attachment weld requirement not applicable to shell to curb...
In our API 650 tank project we have curb angle to shell welding - Butt welding with full penetration.
My query is now the curb angle is considered as permanent attachment and NDT requirement have to be followed accordingly or permanent attachment weld requirement not applicable to shell to...
Dear Members,
As per API 650 section -8 subsection 8.1.2.2.
Regarding radiography of shell plate vertical weld joints API 650 stated as below.
8.1.2.2 The following requirements apply to vertical joints.
one spot radiograph shall be taken in the first 3 m (10 ft) of completed vertical joint of...
Dear respected members,
In our project we have shell to curb angle with butt weld configuration as below.
https://res.cloudinary.com/engineering-com/raw/upload/v1727321119/tips/SHELL_TO_CURB_ANGLE_WELDING_a4s7d7.docx
Radiographic requirements applicable for shell to curb angle butt joints...