Checking a as-built WT18X80 in a vertical position that spans 10'-0", laterally loaded at center (5'-0") with a 7k concentrated load. The load is applied through the stem with a pin that connects through a 6" diameter hole centered @ 13" below the flange. Conservatively designing the tee as...