We have received a print from a customer that has a surface finish callout that is calling for a Ra with a max of 0.2 and a Min of 0.8. I have not seen where the min callout is greater then the max callout. How do you interrupt the callout and where in any standards does it describe how the...
We have an issue that has started since going from NX9.0.3 to NX 12.0.1 and now 12.0.2.9 where the callout for the flat pattern bend radius is using the sheet units and not the model units to define this one value.
We model in Metric, but have our US drawings based on inch units and inch sized...
I have began looking at creation of a global titleblock for our organization and wanted to see if anyone else has dealt with some of the different questions that have been proposed to me.
I was wanting to see how everyone else has dealt with these area of concern dealing with global prints.
How...
Does anyone have this large format printer/plotter that is able to plot from NX9. I had it running before NX9 using a printer driver of HP Designjet 1055cm but for what ever reason, it now give the following error at the printer. Paper size and type are mismatched, it then gives a paper size...
I have read through a lot of the different threads on needing to install the JRE 7 for windows and that it needs to be the 64 bit versions.
The question that I have is that for over 300 users, is it possible to do the install of the JRE 7 on a network drive and have the ugii_env.dat file point...
I have a NX7.5 TBR that I have being displayed in a ribbon enviroment in NX9 but the system command types will not run. I get the error "unknown Action Type: listing out the path and command" We are running NX9.0.3.4 and I can create icons within NX that works, but can't get the ribbon based...
I was wanting to see if anyone could enlighten me on what the command "Custom Background" does and what module you need to be in for the icon to become active. It is currently hidden in NX9.0.3.4, and I have opened realized shape, and the different imaging software but the icon still does not...
I am getting an message dialog box that is saying Error recovery completed for the following error: Internal Error. I get this when I go to the layer dialog box and switch all layers off and then turn them back on. the error shows up when hitting ok to close out of this dialog box. It seems...
I have a situation where in rolling out a new version of NX, I want to have the launch of NX look at the system to see if it can find a program log.txt file, and if so set one custom ugii_eng_cust_ectr.dat file. This configuration would be based on running NX with a SAP PLM system. If it does...
thread561-320528
After reading the information in the attached thread, I was wanting to ask John if there is a way to export the information from the find defaults window so that it can be compared between two different versions. We are getting ready to upgrade from 7.5 to 9 and I am trying to...
NX 7.5.5 - Have an engineer that has a detail view off a base view on Sheet 4 and the detail circle in the base view has disappeared. The circle is around the actual detail view but not in the base view.
have checked the detail circle and it says it is on layer 40. Checked that layer 40 is on...
thread561-313429
As I was looking through the above thread, I have the question: Is there a certified setup for NX and Office that works as it should. I am running on 64OS Windows along with NX7.5.5 on 64bit and office 10. The part families don't update well or at all as I tend to get the...
I am working in NX7.5.5 and have many assemblies that have family members with embedded family members 2 or 3 deep. There are issues with many of these assemblies which I am struggling to figure out how best to do the following.
Identify what is actually causing the issues when trying to load...