  1. SPLIT

    P.Vessels Nozzle loads with exp.joints

    In streight pipe with a e.joints, the pressure trust transmited to the anchors is P*A In dischae nozzle of a púmp , compressor or turbine, the pressure trust is P*A or P*( ex.joint bellows transversal area - pipe internal area ) ? Regards, SPLIT
  2. SPLIT

    Welded Cr Moly for high temperature piping

    Does anybody has used A335 Gr P11 welded pipe for 85 bar 485 °C 24" steam pipe. According ASME B31.3 is OK.?Any restriction ? Regards, SPLIT
  3. SPLIT

    linear or non linear stress analysis

    Which type of piping stress analysis to choose ? : linear or non linear ? I nderstand that the nonlinear ( for suports and for friction ) simulates the real case more acuratelly please your comments SPLIT
  4. SPLIT

    Underground FRP piping hydro test pressure

    recomended or some code hydrotest pressure for gravity and pressure FRP piping There is a 3500 m long pipe.Recomended length to be tested each time (1.5 m diameter ).To intall headers in each extreme of the pipe or a flange ? Sorry so many questions Regards , SPLIT
  5. SPLIT

    FRP soluble demolding

    Are there any kind of problems in using a soluble demolding agent instead of mylard, to avoid a contamination of the product ?
  6. SPLIT

    FRP (GRP) piping optimum design velocity

    FRP piping optimum design velocity, does anybody can recomend?
  7. SPLIT

    ISO vs ANSI Flanges

    ¿Are ISO glanges compatible with ANSI 16.5 flanges, in number of & bolts circle ? regards, Split
  8. SPLIT

    silica filler in reinforced fiberglass

    Does anybody knows the differences in the mechanical properties of a reinforced fiberglass that uses silica - resin central structure and a conventional that uses fiberglass - resin structure
  9. SPLIT

    Whirl in vertical pumps

    ¿Is whirl the only or more frecuent cause of subsynchronic vibrations in vertical pumps ?
  10. SPLIT

    Pressure Vessels internal forces

    In a pressurized vessel with an open nozzle connected to a pipe, the opposed part to the opening of the shell is submited to a pressure distribution that generates a resultant force.The opening can not have an oposed reaction,but the pressure is transmited through the pipe , and somewhere is...
  11. SPLIT

    NFPA-&HDPE underground

    I am desingning an underground HDPE fire fighting water net. ¿Does the HDPE pipe must be UL approved ? Regards, Split
  12. SPLIT

    pump subharmonic vibrations

    ¿Can a centrifugal pump induce subharmonic vibrations? p.e. ¿A 3000 RPM pump and motor , can vibrate at 1200 RPM ?
  13. SPLIT

    Piping Vibrations

    I am performing a dynamical analysis and trying to reduce the vibrations of a FRP piping by ussing a modal analysis.The modes obtained are very near to each other.¿Does it mean that there is no solution , each time that I change the frcuencies by increasing the rigidity, I get near to other...
  14. SPLIT

    steam turbine test

    Please to explain the importace of asking a vaccum dynamic balance test , in a steam turbine spec.
  15. SPLIT

    Steam turbine test

    I would like to know, the importance of asking a vaccum dynamic balance whem specifying a steam turbine
  16. SPLIT

    Compressor chillers or Absorption chillers

    I would like to know if 400t absorption chiller is competitive if using 40°C waste water, to chill water at 5°C
  17. SPLIT

    How to dowload WHAMO?

    I try to download this program , but it should took me a year .does anybody knows a shorter way ?
  18. SPLIT

    PRV's, lay out

    ¿What layout should be better having to reduce steam pressure to 2 levels? 1)High pressure valve to LP+ HP to MP? or 2) HP to MP + MP to LP?
  19. SPLIT

    Optimum Ratio H/R for atmosferic

    Optimum Ratio H/R for atmosferic tanks API 650 ?
  20. SPLIT

    Mill water pipeline

    I am doing a study of materials for a millwater pipeline and I require a installed cost ratio for: - Ductil Iron - polyethylene - Polypropylene - carbon steel - GRP Best regards, SPLIT