  1. mhalarjani

    Paralleling power tf

    Hi every body Hope find aswers for my inquiries I have 2 power transformers Each one 20 mva Each one in separate grid station And distrbution feeders 13.8 kv connected together from both of substations When I paralleled both feeders trips occurred Both feeders have same voltage And hz But...
  2. mhalarjani

    connecting ohl ht cut out fuse ?

    Hi guys sorry for disturbing you .. How can I connect ht cut out fuse on medium voltage on over head line? In attached pic there is 2 points A and B ? Where is the load and source side to point A or B ? What about if I connect opposed...
  3. mhalarjani

    calculating losses power

    Hi everybody I have question about : If I have mv feeder 13.8 kv trip for 4 hours and there is more than 400 customer on that feeder How can calculate losses of money due to that outage.
  4. mhalarjani

    distribution control system

    hallo every body i am working in distribution system in control exactly and iam using paper single line diagram to make my operation with the outside staff to make switching in mv switchgears my inquery i need to develop this control room to be use huge screen toutchable and advanced...
  5. mhalarjani

    pls help for this

    Hi can any one help pls. I have mv cb provided by oc/ef relay supplying dist transformer. When main feeder trip this cb also trip for information this yransformer on seprate feeder but from one main sustation. Thank you
  6. mhalarjani

    detect mv cable faults

    Hello can anyone help me to detect fault in MV cables . in this pic's
  7. mhalarjani

    open secondary ct terminals

    Hi i have question about that CT which marked with true . my quz is : if i removethect secondary wire and the circuit is run is there any problem ? why this ct is steel layers there is no cupper wire turend aroung the core ? thnx alot
  8. mhalarjani

    EFU ct's

    Hi This is CT is installed around mv cable 13.8 kv in RMU and connected to EFI (DEVICE TO DETTECT Fault on mv cable and the flag down .when operator patrole the feeder he can konws the fault pass throughen this circuit . My ques When i open the ct secondary terminals is there any mistake ...
  9. mhalarjani

    inquiry about battery

    Hi every body i have inquiry about the batteris in subsatations : 1- how to select the suitable battery and suitable charger ? 2- is there any relation between the battery and charger ? thanx alot