  1. RJSH

    Difference between storm sewer pipe and a culvert pipe

    I am trying to understand the difference between storm sewer pipe that is designed by Mannings equation vs culvert design. Why can't we size a culvert using Mannings equation, considering that it is conveying flow from one end to other? Can someone explain?
  2. RJSH

    Rational Method and Time of Concentration

    I am evaluating an existing roadside ditch capacity for approx.2,100 ft length. The drainage area contributing to the ditch is a narrow section of roadside ditch area, and half of the pavement, so there is not much flow added. With the rational method, as the Time of Concentration increases, the...
  3. RJSH

    TDH for Vertical Turbine Pump

    When you specify a TDH for Vertical Turbine Pump (or provide TDH info to manufacturer), should it include the column and pump discharge head headlosses too OR the TDH should be at the discharge head connection and the manufacturer will add the losses from discharge head to pump bowl as pump...
  4. RJSH

    Tank Mixing Eductors for Wastewater EQ Basin

    Is tank mixing eductor (TME)good for mixing wastewater eq tank. There is a screen upstream of the EQ basin but you never know what size solids pass through the system. Any potential clogging issues with the eductors in WW application? Feedback from design and/or experience would be appreciated...
  5. RJSH

    Fruits Waste Grinding/Pulverizing

    thread161-281892 With reference to processing of solids fruits wasate (apple, peach, cherry etc. with pits) can someone provide input on equipment that can grind/pulverize the referenced fruits into particles less than 3 mm? llamallama can you provide some input?
  6. RJSH

    Grinder for processing Fruits Waste

    Need a system with a grinder for grinding/pulverizing fruits waste (apple, cherry, peach etc with pits). The particle size off the grinder shall be less than 3 mm. Is there any equipment out there that can guarantee the particle size of less than 3mm? Any input/suggestions/reference?
  7. RJSH

    foam problem in wastewater pipe

    The plant is having issue with foam building up in a vertical pipe that carries filtrate from the belt filter press. The filtrate is collected in an above the ground tank. The vertical pipe is partially filled with water all the time since it is discharging the filtrate to the aboveground tank...
  8. RJSH

    How to get constant flow

    Variable water level in a tank over the time. Need to get a constant Discharge Q by use of a submersible pump (150 gpm). The flow discharge to atmosphere pressure. What flow/pressure control valve should I use? Any suggestions on piping configuration?
  9. RJSH

    WWTP - Post Aeration Air Requirement Based on Fick's Law

    I am trying to understand the calculations of air requirement for Post Aeration Tank based on Fick's Law that I found. Can someone decodify how the followings were calculated based on the data provided? Interfacial Area Between Gas and Liquid A/V Gas Transfer Coefficient KG Time Gas is in...
  10. RJSH

    Cleaning Raw Water Pump Station - VAC Truck Will work??

    Folks, Any suggestion on cleaning method of silt deposition in a raw water pump station. The intake has a 1 mm screen. The pump station wet well invert is 60 ft deep. Will a VAC truck able to pull the deposition out of the wet well? Install a mud pump?? The silt cannot be send back to the river...
  11. RJSH

    What type of Valve to control the flow

    Wastewater Effluent Application- Small flow (200 gpm), pipe size 3inch, single speed pump. The pump runs at approx 360 gpm at 68 ft TDH. I want to reuse the pump by moving the system curve creating more head loss (add more pressure) so that the pump will deliver 200 gpm at 92 ft. What type of...
  12. RJSH

    Pipe Material for Industrial Process Wastewater

    What type of pipe material is in common practice to convey industrial process wastewater (acidic = pH 4)? It appears, in spite of being susceptible to the corrosion, carbon steel pipe is still used widely in the industrial wastewater with allowance for scraficing thickness for corrosion (i.e...
  13. RJSH

    Use of Carbon Steel Tank for Wastewater

    We are reusing a existing carbon steel tank to hold industrial wastewater of acidic nature ( lower value upto pH 4) for temporaily storage when the treatment system is in upset condition. What are the items to be considered for this conversion. What would be the minimum D.O. to be maintained...
  14. RJSH

    Design Flow for Digester

    IS Aerobic/Anaerobic Digester designed for 30-days maximum flow or 7-days peak flow? What is the standard practice?
  15. RJSH

    Aerobic Digester VSS Destruction % Calculation Formula

    I am looking for assistance in finding a formula to find Aerobic Digester VSS Destruction % formula based on SRT, VSS, and nbVSS, Kd. I came across a formula containing above parameters, but I couldn't find the same formula containing nbVSS in any of the reference such as Metcalf Eddy, or WEF...
  16. RJSH

    Pump Operation at Start Up

    May be a very dumb question, but just thought there is nothing wrong to ask- When a centrifugal pump is started against a closed check valve, will the pump operation move from left to right or right to left on the pump curve? (Start with zero head or start with zero flow?)
  17. RJSH

    Back Pressure Valve vs Back Pressure Regulating Valve

    This question is pertaining to water works. I am seeing two terms or two equipment - back pressure valve and back pressure regulating valve. Wondering what is the difeerence between these two (in terms of inlet and outlet pressure)
  18. RJSH

    Significance of Pump Shut Off Head

    What is the significance of Pump Shut of Head in terms of pump operation and mainteance, piping system, valves design, and other pump station design parameters? Thanks in advance for your input.
  19. RJSH

    900 rpm vs 1200 rpm VT pump

    Hi all, I am working on writing a spec. for a fairly large Vertical Turbine Pump . During the pump selection procedure from various manufacturers, we had more manufacturers that they could meet the design conditions at lower speed of 900 rpm and one manufacturer being at 1200 rpm. My question is...